<br />08-51-00 - 5 ALUMINUM WINDOWS – SERVICE BUILDING 08-51-00 - 5 <br /> <br /> 6. YKK-AP <br /> <br /> 7. Architect approved equal required prior to bidding <br /> <br />E. Other window manufacturers requesting to be considered “equal” and included in this Project <br />must submit in addition to the test data enumerated in the preceding Sub-Section B, the <br />following: detailed Shop Drawings for each window type and configuration identifying each <br />component of each window and mull/panning profiles, a sample (24" x 36") window <br />assembly, complete with the specified hardware, fixed over Project out sash assembly, 2 ½" <br />frame depth and accessories for this Project. <br /> <br />1.04 SUBMITTALS: Comply with Division - 1 requirements. <br /> <br />A. Provide the submittals package in a timely manner to meet the construction schedule. Allow <br />ample time for a full resubmittal of Shop Drawings without affecting the Project overall <br />schedule and the window delivery schedule, if the reviewed conditions/quality of the first <br />submittal require a resubmittal. <br /> <br />B. Product Data: Submit manufacturer's original published product data (no faxed sheets) with <br />all proposed components and accessories highlighted. <br /> <br />C. Test Reports: Provide test reports from AAMA and ASTM accredited laboratories certifying <br />the performance results as specified in Sub-Part 1.03. <br /> <br />D. Certification letter from window manufacturer stating that the tested window(s) meet and/or <br />exceed the criteria for the AAMA window type(s) specified. <br /> <br />E. Warranties: Submit the final draft of the warranty certificates as specified in this Section as <br />they will appear in the closeout documents package. W arranties to be included: <br /> <br /> 1. Window Manufacturer’s W arranty <br /> <br /> 2. Pigmented Organic Finish Manufacturer’s W arranty <br /> <br /> 3. Insulated Glass Manufacturer’s W arranty <br /> <br />F. Furnish complete Shop and setting Drawings and engineering calculations for review prior to <br />fabrication. The Shop Drawings shall be prepared wholly by the window manufacturer or by a <br />window manufacturer’s authorized third-party detailer exclusive from the Contractor. Shop <br />Drawings prepared by the Contractor, excluding Contractor’s review information added <br />thereon, will be cause for rejection of the Drawings in full without further additional review; <br />resubmittal will be required in accordance with this paragraph and Section.. <br /> <br /> Shop Drawings: <br /> <br />1. Show quarter-inch to foot elevations, and full scale details of frames, hardware, and <br />detailed anchorage to surrounding construction. Include - in the drawings set - a <br />building plan drawing for each floor level showing where each window type is to be <br />installed. The Drawings shall have all dimensions noted for the window units and <br />rough opening requirements. Drawings reduced in scale, sheet size, etc. will be <br />considered not in compliance with the Project requirements, rejected and will require <br />resubmittal. <br /> <br />2. Refer to Sub-Part 1.05 for additional requirements to be included as part of the shop <br /> Drawings. <br />