3. 420 South Eddy Street_COA 2022-0606
sbend
>
Public
>
Historic Preservation
>
2022
>
June
>
3. 420 South Eddy Street_COA 2022-0606
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2022 2:16:35 PM
Creation date
6/14/2022 2:15:52 PM
Metadata
Fields
Template:
South Bend HPC
HPC Street Address
420 South Eddy Street
HPC Document Type
Certification
HPC Local Landmark
i. South Bend
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />08-51-00 - 2 ALUMINUM WINDOWS – SERVICE BUILDING 08-51-00 - 2 <br /> <br />3. Design Requirements: <br /> <br />a. The window manufacturer is responsible for designing system, including <br />installation instructions and necessary modifications to meet specified <br />requirements and maintain visual design concepts. <br /> <br />b. Requirements shown by details are intended to establish basic dimension of <br />unit, sight lines and profiles of members. <br /> <br />c. Provide assemblies free from rattles, wind whistles and noise due to thermal <br />and structural movement and wind pressure. <br /> <br />d. Installation instructions are to take into account building peculiarities and <br />expansion and contraction movements so there is no possibility of <br />loosening, weakening or fracturing connection between units and building <br />structure or between units themselves. <br /> <br />e. Provide for expansion and contraction due to structural movement without <br />detriment to appearance or performance. <br /> <br />f. Evacuate water without infiltration to interior from exterior face of wall, water <br />entering joints, and condensation occurring within windows, by drain holes <br />and gutters of adequate size or other acceptable method. <br /> <br />g. Provide concealed fastening wherever possible. <br /> <br />B. The window manufacturer is responsible for factory glazing all window units and types <br />specified herein. The final glass color tint selection will be made by the Architect from <br />samples submitted by the Contractor. <br /> <br />C. This Contractor is responsible for all perimeter - exterior and interior - sealant installations at <br />each window location. <br /> <br />D. This Contractor is responsible for field measurements of openings. See Sub. Part 1.05 for <br />additional requirements. <br /> <br /> E. Sunshade shall be designed as an integral part of aluminum architectural window <br /> system. <br /> <br /> 1. A proposal drawing showing full size details of all sunshade and window system <br /> components including all anchors, sunshade supports, and building attachments. <br /> <br /> 2. Engineering calculations documenting compliance with requirements of <br /> Section 1.05. <br /> <br />1.03 QUALITY ASSURANCE: <br /> <br />A. Windload Criteria: <br /> <br />1. The applicable State Building Code, current edition, having jurisdiction over the <br />location of the Project. <br /> <br />2. The system shall be designed to withstand the following loads normal to the plane <br />of the wall: <br /> <br />a. Positive pressure of 20 psf at non-corner zones.