My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
April 2010
sbend
>
Public
>
Historic Preservation
>
Meeting Minutes and Recordings
>
HPC Meeting Minutes 2010
>
April 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/11/2019 1:16:18 PM
Creation date
6/8/2020 10:14:20 AM
Metadata
Fields
Template:
South Bend HPC
HPC Document Type
Minutes
BOLT Control Number
1001362
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
will be standard concrete with a broom finish. The size details are per floor <br />plan. See attachment/label #2. <br />3.) The HVAC penetrations for utility supply, exhaust, and fresh air intake <br />are labeled on the plan and will exit via the existing north window well <br />location. The A.C. condensors (2) locations are also labeled in respect to the <br />committee's over all view of the property, these will be in the planting space <br />of the back entry. We figure we will be able to disguise them with plantings <br />and landscaping as best as possible. See attachment/label #3. <br />4.) The electrical service is going to be redone so that it can be buried under <br />ground instead of it's current existence of overhead supply. We will also <br />have the phone line buried to the building as well. Other exterior electrical <br />that we will be conducting include a lamp light on the'-power pole on the <br />south corner of the property to light up the back half of the property for <br />security reasons, installing (4) lamp lights on poles with design relevant to <br />the early 1900`s time period, installing recessed lighting in the porch soffit <br />for safety and affect lighting. See attachment/label #4. <br />5.) The front door will be reused and refinished. We will be removing the <br />closer on the exterior of the door and installing something internally. The <br />door will be refaced, new hinges matching the existing installed, the <br />hardware will be reused and refinished. The trim that meets the granite from <br />the front door will be remade to match the same profile - and will be made of <br />oak, as is the current species. The face of the exterior door will be in oak <br />veneer as it currently exists. Bartow Builders has reviewed the composition <br />of the door and deemed it salvageable.- The final aspect of this door will be <br />weather stripping for proper sealing. This should not affect the approval of <br />this committee as the stripping will be done internally. Please see <br />attachment/label #5. <br />6.) In order to meet the ever growing population with disabled needs <br />StoneMor, the property owner, has requested to make the building ADA <br />accessible so that all of their clients and families can enjoy the benefits of <br />this building as well as their services. The plan we have provided shows the <br />details of a ramp that we have discussed with Jim Markle at South Bend <br />Building Inspection. Jim has requested from us to define the ramp and make <br />it only as wide as it need be. This will include a railing system that will <br />mount on the building and pass through the window ever so slightly and a <br />railing that will be mounted into the concrete down the center of the walk <br />