in the upper section of the ALS cabinet. <br />Y�N_ <br />3.12 115 VOLT AC POWER <br />There shall be 115 volt AC wiring furnished. A three -wire system is used for <br />powering medical equipment, battery charger, etc. This electrical system, including <br />wiring and associated equipment, shall comply with AMD STD 009, 120V AC <br />Electrical Systems. The system shall incorporate a hospital grade GFI (Ground Fault <br />Interrupt) device with a 20 amp circuit breaker that can also be used as a disconnect <br />switch for the interior 116 volt outlets. The GFI device shall be located on the street <br />side in the action area. When an inverter is specified, an automatic transfer switch <br />shall be furnished which will automatically turn off the inverter 115 volt supply when <br />the 115 volt utility shoreline power is applied. <br />3.13 INVERTER <br />A Vanner, model 420-1050CUL inverter shall be provided and installed. The Vanner <br />20-1050CUL/CULW AC Power System shall combine a powerful DC to AC power <br />inverter with an automatic battery charger/conditioner and a 30-amp AC transfer <br />switch. When connected to shore power (AC utility power) the vehicle's battery is <br />charged, than automatically maintained in full charge condition. The shore power <br />shall be automatically connected to the system's AC output receptacle to supply <br />power to the AC loads. When shore power is disconnected, (vehicle underway) the <br />automatic transfer switch shall connect the AC output receptacle to the power <br />inverter, which obtains power from the 12 volt battery. <br />The 20-1050CUUCULW system shall contain a front panel LED indicator status <br />panel and interface connector for the remote monitor/control unit. The inverter shall <br />be mounted in the lower forward corner of the D2 compartment. ® <br />Y ✓N <br />3,14 EXTERIOR SNORE POWER <br />There shall be a Kussmaul 115 volt "Auto -Eject" plug rated at 20 amps or more with <br />a spring -loaded cover assembly, UL listed for exterior use, located on the left side of <br />the ambulance body close to the driver's door. The plug shall be equipped with a <br />Dynamic Disconnect Switch. This shall energize the vehicle's 115 volt AC circuit <br />from an exterior power source. This connector must be labeled: "115 volt AC, 60 Hz, <br />20 amp power supply". <br />3.15 INTERIOR 115 VOLT AC OUTLETS <br />There shall be three (3) three -wire duplex 115-volt AC hospital grade receptacles. <br />There shall be one [1] in the primary action area, one [1] in the second action area <br />and one [1] in the ALS cabinet. There shall be red indicator lights located within <br />each 115-volt outlet to indicate a live "hot" circuit. Add -on style indicators are not <br />acceptable. The receptacles shall be clearly labeled: "115 VAC". <br />Y,v <br />3.15.1 Two (2) additional three -wire duplex 115-volt AC hospital grade receptacles <br />shall also be provided and installed. The one (1) shall be located over the squad <br />bench and one (1) in the lower ALS cabinet. There shall be red indicator lights <br />located within the 115-volt outlet to indicate a live "hot" circuit. It shall be clearly <br />labeled: 115 VAC". <br />YZN� <br />29 <br />