My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2025
>
Opening of Quotations/Proposals/Qualifications
>
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 4:25:16 PM
Creation date
2/11/2025 1:57:02 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
2/11/2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
System No. W-L-7153 <br />2. Steel Duct — Galy steel duct to be installed concentrically or eccentrically within the firestop system. Duct to be rigidly supported on both <br />sides of wall assembly. <br />A. Spiral Wound HVAC Duct — Nom 20 in. (508 mm) diam (or smaller) No. 24 MSG (or heavier) galv steel spriral wound duct. <br />B. Sheet Metal Duct — Nom 12 in. (305 mm) diam (or smaller) No. 28 MSG (or heavier) gals sheet steel duct. <br />3. Duct Insulation* — Nom 1-1/2 in. or 2 in. (38 or 51 mm) thick glass fiber batt or blanket (min 314 pcf or 56 kglm3) jacketed on the outside with <br />a foil-scrim-kraft facing. Longitudinal and transverse joints sealed with aluminum foil tape. During the installation of the fill material, the batt or <br />blanket shall be compressed 50% such that the annular space within the firestop system shall be min 114 in. (6 mm) to max 1-112 in. (38 mm). <br />See Batts and Blankets - (BKNV) category in the Building Materials Directory for names of manufacturers. Any batt or blanket meeting the <br />above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index 50 or <br />less may be used. <br />4. Fill, Void or Cavity Material* — Sealant — Min 518 in. (16 mm) thickness of fill material applied within annulus, flush with both surfaces of wall. <br />If voids develop after the fill materials cures, the voids shall be sealed with additional fill material. <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE Sealant or FS-ONE MAX Intumescent Sealant <br />* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), <br />respectively. <br />Reproduced by HILTI, Inc. Courtesy of <br />Underwriters Laboratories, Inc. <br />November 15, 2017 <br />Hilti Firestop Systems <br />M <br />Ln <br />T <br />ti <br />J <br />2of2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.