My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2025
>
Opening of Quotations/Proposals/Qualifications
>
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 4:25:16 PM
Creation date
2/11/2025 1:57:02 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
2/11/2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
�.ss I F,fio <br />G <br />c VNW us <br />Classified by <br />Underwriters Laboratories, Inc. <br />to UL 1479 and CAN/ULC-S115 <br />System No. W-L-7155 <br />ANSI/UL1479 (ASTM E814) <br />F Ratings —1 and 2 Hr (See Item 1) <br />T Ratings — 0 Hr <br />L Rating at Ambient — Less Than 1 CFM/sq ft <br />L Rating at 400 F — Less Than 1 CFM/sq ft <br />CAN/ULC S115 <br />F Ratings —1 and 2 Hr (See Item 1) <br />FT Ratings — 0 Hr <br />FH Ratings —1 and 2 Hr (See Item 1) <br />FTH Ratings — 0 Hr <br />L Rating at Ambient — Less Than 1 CFM/sq ft <br />L Rating at 400 F — Less Than 1 CFM/sq ft <br />1. Wall Assembly — The 1 or 2 hr fire -rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner described <br />in the individual U400, V400 or W400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following <br />construction features: <br />A. Studs — Wall framing shall consist of min 3-1/2 in. (89 mm) wide steel channel studs spaced max 24 in. (610 mm) OC. Additional steel studs <br />shall be used to completely frame the opening. <br />B. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (1.22 m) wide with square or tapered edges. The gypsum board type, thickness, number of <br />layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design in the UL Fire Resistance Directo <br />Max area of opening is 73.7 sq ft (6.85 m2) with a max dimension of 104 in. (2.64 m). ry. <br />The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. <br />2. Steel Duct — Max 100 in. by 100 in. (2.5 by 2.5 m) galv steel duct to be installed either concentrically or eccentrically within the firestop system. <br />The duct shall be constructed and reinforced in accordance with SMACNA construction standards. The space between the steel duct and <br />periphery of opening shall be min 0 in. (point contact) to max 2 in. (51 mm). Steel duct to be rigidly supported on both sides of the wall assembly. <br />Reproduced by HILTI, Inc. Courtesy of <br />Underwriters Laboratories, Inc. <br />HIM Firestop Systems December 26, 2017 <br />Page: 1 of 2 <br />7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.