My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Proposals - WWTP Solar Guaranteed Energy Savings Contract Proj. No. 124-015 - Ameresco
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2024
>
Opening of Quotations/Proposals
>
Opening of Proposals - WWTP Solar Guaranteed Energy Savings Contract Proj. No. 124-015 - Ameresco
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2024 3:13:43 PM
Creation date
5/28/2024 3:12:07 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
5/28/2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
283
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br /> <br /> <br />“Page content is subject to Confidentiality Restrictions” <br /> <br />City of Arvada, Colorado | Project #37213 | M&V Report – Year 2 | Page 28 <br /> <br /> <br />City of Arvada, Colorado <br />ECM 14: MZU Conversion to VAV <br />Savings Unit Guaranteed Verified <br />kWh 43,531 40,747 <br />Dollars $1,620 $1,519 <br /> <br />Overview of ECM <br />This measure included the installation of VFDs on multizone units (MZU) at Indiana Shops, Streets Maintenance, and <br />Wastewater Operations. Changes were made to the control sequences to allow supply fans to run at lower speeds when <br />heating or cooling demands are less than design conditions. New motors were also installed for the two MZUs at <br />Wastewater Operations. <br /> <br />Commissioning <br />After the installation of the ECM, commissioning activities were performed in accordance with Schedule Q of the EPC. <br /> <br />The functionality of the control strategy, that is intended to slow down the supply air fan as the load on the MZU <br />decreases, was field verified. <br /> <br />Installation of the motors and VFDs were inspected and found to be acceptable by Ameresco. <br /> <br />Correct phase rotation of the fans and integration of the BACnet enabled VFDs w as verified. <br /> <br />Measurement & Verification <br />The M&V Plan for this ECM was based on Agreed Upon Savings. The savings for this measure are achieved upon <br />project acceptance. <br /> <br />Although the savings are agreed upon for this ECM, Ameresco has reduced the verified savings due to the units at <br />Indiana Shops operating at a faster speed than expected. This was due to a change in programming that was made <br />necessary by the fact that the unit was calling for heat, but it would not fire at airflow as low as initially programmed. <br />This adjustment will continue for future reporting periods. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.