My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10.26.2021-SBN-Standards-Manufacturer-Additions-Minor-Revisions-final
sbend
>
Public
>
Public Works
>
City of South Bend Construction Standards & Specifications
>
10.26.2021-SBN-Standards-Manufacturer-Additions-Minor-Revisions-final
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/6/2024 3:44:43 PM
Creation date
5/6/2024 3:43:30 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
City Property
Document Date
5/6/2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
W <br />12' <br />A <br />A <br />B <br />B <br />A10'Drainage Structure <br />A <br />3 <br />0 <br />' <br /> <br />R <br />. <br />B BB B <br />Pay Limits include Sidewalk <br />to Expansion Joint <br />1.5%6"1"L <br />L/2 L/2 <br />B <br />8" <br />Typ.8"Typ.GradeBreak6/26/18 <br />CITY OF SOUTH BENDItemRevision <br />STANDARD <br />EFFECTIVE DATE: <br />REF STD SPEC SEC <br />APPROVED/REVISED BY THE BOARD OF PUBLIC WORKS <br />STANDARDS FOR DESIGN <br />AND CONSTRUCTION <br />Kara M. Boyles, Ph.D., P.E. Date <br />DRIVES AND APPROACHES - URBAN ALLEYS 2-27 <br />2-2 <br />June 26, 2018 <br />SECTION 2 - STREETS AND PATHS <br />ALLEY APPROACH - PLAN <br />ALLEY APPROACH <br />SECTION A-A <br />NOTES: <br />1.Class "A" concrete to be used in all approaches. <br />2.Radii as specified. <br />3.Sidewalk as per INDOT Standard Drawings. <br />4.Contraction joints required on approach center when W is 12 ft. or more. <br />5."Curing Concrete" - As per INDOT Standard Specifications Section 501 (Paragraph <br />501.20) use a curing compound immediately (white membrane only accepted cure). <br />6.Concrete forms shall be at least as high as the thickness of the item shown. Lumber <br />of nominal dimensions shall not be used if less than the design thickness. <br />7.All approaches shall require proper compaction, as per INDOT Standard <br />Specifications Section 207. <br />8.Blankets shall be utilized on concrete when temperature is expected to fall below 50° <br />F. <br />9.Radii may be reduced to 20' if travel way is separated by parking. <br />LEGEND <br />Expansion Joint - Full Joint <br />Contraction Joint <br />W Width <br />L Length
The URL can be used to link to this page
Your browser does not support the video tag.