Laserfiche WebLink
A <br />A <br />A BB <br />A <br />A <br />A <br />5'-0" W <br />40'-0" Max. <br />W <br />5'-0"3'-6" <br />Max.Tree Lawn 5'-0" Typ. <br />Slope 1 4"/Ft. <br />Toward Curb <br />Service Walk <br />Where Permitted <br />BB B B AB <br />Existing Private Walk <br />5'-0" <br />1.5%4"Typ.6/26/18 <br />CITY OF SOUTH BENDItemRevision <br />STANDARD <br />EFFECTIVE DATE: <br />REF STD SPEC SEC <br />APPROVED/REVISED BY THE BOARD OF PUBLIC WORKS <br />STANDARDS FOR DESIGN <br />AND CONSTRUCTION <br />Kara M. Boyles, Ph.D., P.E. Date <br />DETAILS - RESIDENTIAL SIDEWALK 2-28 <br />2-2 <br />June 26, 2018 <br />SECTION 2 - STREETS AND PATHS <br />NOTES: <br />1.Class "A" concrete to be used in all walks and approaches. <br />2."Curing Concrete"- As per INDOT Standard Specifications Section 501 <br />(Paragraph 501.20). Use a curing compound immediately (white membrane only <br />accepted cure). <br />3.Concrete forms shall be at least as high as the thickness of the item shown. <br />Lumber of nominal dimension shall not be used if less than the design thickness. <br />4.Proper compaction per INDOT Standard Specification Section 604 (Paragraph <br />604.03(b)) is required for all walks and approaches. <br />5.Blankets shall be utilized on concrete when temperature is expected to fall below <br />50°F. <br />6.No wire mesh or rebar allowed in any concrete (sidewalk, approaches, curbs) <br />placed within the right of way. <br />CONCRETE SIDEWALK - RESIDENTIAL <br />SECTION A-A <br />LEGEND: <br />Expansion Joint - Full Depth <br />Contraction Joint <br />W Width