Laserfiche WebLink
Quantity Calculations Calc's By:LSG <br />City of South Bend 2022 Road Rehab CHK By: <br />Jackson Rd From Station To Station <br />Construction Detail Sheet <br />Legend <br />Item Description Quantity Unit Comments <br />PCCP for Approaches, 6"3201 SFT 356 SYS <br />Subgrade Treatment, Type II 3201 SFT 356 SYS <br />HMA Surface, Type B 87272 SFT 801 TON Depth = 1.5" (165#/SYS) <br />HMA Intermediate, Type B 87272 SFT 1334 TON Depth = 2.5" (275#/SYS) <br />HMA Base, Type B 87272 SFT 4267 TON Depth = 8.0" (880#/SYS) <br />Subbase, No. 53 87272 SFT 3230 TON Depht = 6.0" (0.333T/SYS) <br />Subgrade Treatment, Type II 87272 SFT 9697 SYS <br />13 Standard Curb 116 LFT 116 LFT <br />Combination Curb & Gutter, Type B 408 LFT 408 LFT <br />Subbase, No. 53 116 SFT 46 TON Depht = 6.0" (0.333T/SYS) <br />Subgrade Treatment, Type II 1224 SFT 136 SYS Width = 3' <br />Combination Curb & Gutter, Type A (Rolled Curb)563 LFT 563 LFT <br />Subbase, No. 53 1224 SFT 63 TON Depht = 6.0" (0.333T/SYS) <br />Subgrade Treatment, Type II 1689 SFT 188 SYS Width = 3' <br />Mulched Seeding, Type U 12000 SFT 1333 SYS <br />Topsoil 2000 CFT 74 CYS Depth = 2"29 <br />C <br />17 <br />Quantity from AutoCad <br />Drawing <br />15 <br />K