Laserfiche WebLink
8.0 INTERIOR PATIENT COMPARTMENT COMPONENTS <br />Patient Compartment Sound Levels: This vehicle shall provide an interior working <br />environment in which the ambient noise level is less than 80 dB as measured <br />according to AMD Standard 006, Sound Level Test Code for Ambulance <br />Compartment Interiors. <br />Patient Compartment Carbon Monoxide Levels: This vehicle shall provide an interior <br />working environment in which the carbon monoxide level is less than 10 ppm as <br />measured in accordance with AMD Standard 007, Carbon Monoxide Levels for <br />Ambulance Compartment Interiors. <br />Y N <br />8.1 CABINET GLASS <br />All cabinet doors incorporating acrylic glass, as sliding or hinged windows shall have <br />.250" thick smoked acrylic Plexiglas® as the standard material and 3/8" where <br />otherwise specified. <br />8.2 STAINLESS STEEL ROUND LATCHES <br />Stainless Steel Round Southco locking latches (or equal) shall be provided on each <br />door where applicable. <br />Y N <br />8.3 CABINETRY <br />The cabinetry in the patient compartment shall have picture framed window face <br />fronts fabricated from lightweight smooth aluminum material and laminated with a <br />minimum .028" Formica (or approved equal). The shelves and the supporting <br />structure shall be non -wood material and laminated with a minimum of .028" Formica <br />on both sides. <br />Non -supportive partitions shall be lightweight smooth aluminum material and <br />laminated with a minimum of .028" Formica on both sides. All vertical outside <br />corners and protruding edges of overhead storage shall be capped with 5" radius <br />satin finish anodized aluminum moldings or padded vinyl. <br />All cabinetry shall be sealed and molded to the floor with bright -anodized aluminum <br />molding. All interior materials, cabinetry, vinyl, foam, and installation used shall meet <br />or exceed FMVSS 302 requirements on flammability of interior materials (where <br />applicable). X/ <br />Y (� N <br />8.4 COUNTERTOPS <br />The countertop in the primary action area of the patient compartment shall be non - <br />wood material, laminated with a minimum .028" stainless steel. The top shall be a <br />pan style with all seams sealed. <br />YXN <br />8.4.1 The countertop in the second action area of the patient compartment shall be <br />non -wood material, laminated with a minimum .028" stainless steel. The top shall be <br />a pan style with all seams sealed. <br />