9.0 PATIENT COMPARTMENT LIGHTS <br />Patient compartment lighting shall consist of eight (8), LED dome lights with polished <br />bezels, switched from the action area control console. These lights shall be high <br />intensity LED with clear lenses. The lights shall be activated in separate banks of <br />four (4) lights each. There shall be one (1) bank over the squad bench and one (1) <br />bank over the primary cot. Two (2) switches shall be provided in the action area <br />console, each with high/off/low positions for independent operation of each bank. All <br />eight (8) LED dome lights shall be activated on "LOW" when either the curbside entry <br />door or rear entry doors are opened. There shall be a three -minute time delay <br />system activated by opening the entry doors. This system shall be battery hot and <br />turn the lights "OFF" at the three -minute pre-set time. No ceiling light shall protrude <br />into the patient compartment by more than 1.25". <br />9.0.1 THINLITE LIGHTS <br />Four (4) Trucklite model #80251C 18" LED panel lights, recessed into the ceiling <br />shall also be provided and installed. One (1) on/off position switch shall be provided <br />in the action area console. <br />9.0.2 An LED strip light shall be provided and installed in the primary action area. <br />This light shall have a manual "on/off' switch. <br />9.0.3 A rotary timer system shall be provided for the fluorescent lights. The system <br />shall be preset to automatically turn the lights off after activating. The timer shall be <br />from 5-60 minutes. <br />The patient compartment interior lights must meet the requirements set forth in AMD <br />Standard Test 016 Patient Compartment Lighting. <br />10.0 CEILING HEADLINER <br />The patient compartment headliner shall be constructed of a durable, high -gloss <br />white, plasticized Marlite, backed with a non -rigid non -wood material. The headliner <br />shall be securely affixed to the roof bows and to the .090" aluminum accessory plate <br />welded to the roof structure. There shall be a full-length inspection access/wire race <br />in the center of the ceiling, which provides access to the wiring harness and <br />antennae bases/leads. The access shall have removable padded vinyl covers. <br />10.1 FLOORING <br />A one-piece non -wood material sub -floor on all patient area floors less than 144" in <br />length shall be installed on top of the .090" thick aluminum sheet. The sub -floor shall <br />be securely fastened with sheet metal screws long enough to penetrate the 2" x 2" <br />body tubes below the .090" aluminum sheet. This process shall create a sandwich <br />effect for long lasting durability and a solid surface. All screws shall be filled and <br />sanded to provide a smooth surface for the linoleum covering. Floor lengths longer <br />than 144" shall include a two-piece plywood underlayment. Vinyl, anti-skid, <br />commercial grade, heavy-duty, non -porous floor covering shall be applied to the <br />entire floor in a one-piece seamless application. This commercial inlaid sheet vinyl <br />Y N <br />Y N <br />911111111111011 <br />Y N <br />Y N <br />