Laserfiche WebLink
15.1 The cabinet shall have a vertically hinged door and shall be provided with a <br />locking stainless-steel round latch. This door shall hinge on the left side for ease of <br />maintenance and repair. <br /> Y___N___ <br /> <br />16.0 WALK-THROUGH WITH POCKET DOOR <br /> <br />There shall be an opening approximately 52" high x 20" wide between the chassis <br />cab and the box module. <br /> Y___N___ <br />16.1 An aluminum partition wall framed with .125" x 2" x 2" aluminum tubing placed <br />on 16" centers and plated with .060" aluminum formed and welded to the roof, both <br />sides, and floor shall be installed. The patient compartment side of the partition shall <br />be covered with 1/4" plywood laminated with a minimum of .028" plastic. The driver's <br />side of the partition shall be covered with the OEM wall as well as a mildew resistant <br />marine style carpet of a color that matches the cab interior colors. <br /> Y___N___ <br />17.0 EQUIPMENT FURNISHED <br /> <br />The ambulance cab shall be equipped with an OEM supplied in-dash air conditioner <br />and a hot water heater. The patient compartment shall be equipped with a <br />combination hot water heater/air conditioner and a power exhaust vent. Front and <br />rear heaters and air conditioners shall operate as separate and independent <br />environmental systems. The controls for the rear environmental systems shall be <br />located in the action area switch panel. The addition of the rear HVAC system shall <br />have no deleterious effect upon the chassis system and especially the windshield <br />defroster system as described in FMVSS 103, Windshield Defrosting and Defogging <br />System. <br /> Y___N___ <br />17.1 A combination heater/air conditioner having an air output of 650 cfm at 0 static <br />pressure, a cooling capacity of 32,000 BTU and a heating capacity of 35,000 BTU <br />shall be installed above the walk-through door on the front bulkhead. There shall be <br />two insulated plenums running the full length of the modular body in the ceiling with <br />(4) adjustable outlet vents in each plenum. There shall also be one adjustable outlet <br />vent on the front bulkhead. This system shall be certified to KKK standards by a <br />third-party test facility and a copy of the test results shall be included with the bid. <br /> Y___N___ <br />17.2 For durability purposes, metal “Y’s” shall be used for heater hose tie in. <br /> Y___N___ <br />17.3 An auxiliary air conditioner condenser with dryer shall be provided under the <br />body. <br /> Y___N___ <br />17.4 The patient compartment heat and air conditioning shall be controlled and <br />maintained through a digital, manually controlled thermostat. <br /> Y___N___ <br /> <br /> <br />18.0 ALS CABINET <br /> <br />An Advanced Life Support cabinet shall be provided in the right side of the forward <br />wall. It shall be divided into sections to accommodate the storage of sensitive <br />equipment and supplies, such as ALS equipment, Laerdal charger, medical boxes, <br />etc. The ALS cabinet and all shelves shall be finished with black Line-X, sprayed on <br />rubber coating. <br /> Y___N___