Laserfiche WebLink
.250” thick smoked acrylic Plexiglas® as the standard material and 3/8” where <br />otherwise specified. <br /> Y___N___ <br />8.2 STAINLESS STEEL ROUND LATCHES <br /> <br />Stainless Steel Round Southco locking latches (or equal) shall be provided on each <br />door where applicable. <br /> Y___N___ <br /> <br />8.3 CABINETRY <br /> <br />The cabinetry in the patient compartment shall have picture framed window face <br />fronts fabricated from lightweight smooth aluminum material and laminated with a <br />minimum .028" Formica (or approved equal). The shelves and the supporting <br />structure shall be non-wood material and laminated with a minimum of .028" Formica <br />on both sides. <br /> <br />Non-supportive partitions shall be lightweight smooth aluminum material and <br />laminated with a minimum of .028" Formica on both sides. All vertical outside <br />corners and protruding edges of overhead storage shall be capped with 5" radius <br />satin finish anodized aluminum moldings or padded vinyl. <br /> <br />All cabinetry shall be sealed and molded to the floor with bright-anodized aluminum <br />molding. All interior materials, cabinetry, vinyl, foam, and installation used shall meet <br />or exceed FMVSS 302 requirements on flammability of interior materials (where <br />applicable). <br /> Y___N___ <br />8.4 COUNTERTOPS <br /> <br />The countertop in the primary action area of the patient compartment shall be non- <br />wood material, laminated with a minimum .028" stainless steel. The top shall be a <br />pan style with all seams sealed. <br /> Y___N___ <br /> <br /> <br />8.4.1 The countertop in the second action area of the patient compartment shall be <br />non-wood material, laminated with a minimum .028" stainless steel. The top shall be <br />a pan style with all seams sealed. <br /> <br /> <br /> Y___N___ <br />9.0 PATIENT COMPARTMENT LIGHTS <br /> <br />Patient compartment lighting shall consist of eight (8), LED dome lights with polished <br />bezels, switched from the action area control console. These lights shall be high <br />intensity LED with clear lenses. The lights shall be activated in separate banks of <br />four (4) lights each. There shall be one (1) bank over the squad bench and one (1) <br />bank over the primary cot. Two (2) switches shall be provided in the action area <br />console, each with high/off/low positions for independent operation of each bank. All <br />eight (8) LED dome lights shall be activated on "LOW" when either the curbside entry <br />door or rear entry doors are opened. There shall be a three-minute time delay <br />system activated by opening the entry doors. This system shall be battery hot and <br />turn the lights “OFF” at the three-minute pre-set time. No ceiling light shall protrude <br />into the patient compartment by more than 1.25”. <br /> Y___N___