Laserfiche WebLink
the rear entry doors. <br /> Y___N___ <br /> <br />7.10 POWER DOOR LOCK ACTIVATION <br /> <br />The patient compartment door locks shall be wired to the chassis power door locks. <br /> Y___N___ <br /> <br />7.11 STAINLESS STEEL DOOR SILL PROTECTION <br /> <br />There shall be a 20 ga. formed stainless steel compartment doorsill protection for all <br />exterior compartments. The stainless protector shall be affixed with heavy-duty <br />double-sided tape to the top surface of the doorsill and extend over the radius edge. <br /> <br /> Y___N___ <br />7.12 COMPARTMENT ILLUMINATION <br /> <br />Each exterior compartment shall be illuminated with 4.25” round, Liteco incandescent <br />lights Model #69000200 (or equal). These lights shall have clear Lexan lenses and <br />be recessed into the compartment sides and/or ceiling above and below any <br />specified shelves. Each door shall have an individual automatic switch to signal a <br />“door or compartment open” condition and to turn on interior lighting when the door is <br />opened. The switches shall be Sentrol heavy duty, magnetic reed switches mounted <br />in the doorframe header interior to the protective door seal. <br /> Y___N___ <br />7.13 OXYGEN TANK MOUNT <br /> <br />One fully adjustable oxygen tank mount shall be installed in the exterior compartment <br />D1. This mount shall accommodate an “M” type oxygen tank. This oxygen tank <br />retention system must meet or exceed AMD Standard 003, Oxygen Retention <br />System. <br /> Y___N___ <br />7.13.1 One (1) fixed shelf shall be provided in the D1 compartment located above the <br />oxygen tank. <br /> Y___N___ <br />7.13.2 Two (2) Model # 166AH Gear Hooks shall be mounted one (1) on the forward <br />wall and one (1) on the rear wall of the D1 compartment. Exact hook placement <br />shall be determined at the pre-build meeting. <br /> Y___N___ <br />7.14 ADJUSTABLE SHELVES <br /> <br />One (1) adjustable shelf will be provided and installed in the D-2 compartment. Each <br />shall be easily adjusted to accommodate equipment/supply requirements. <br /> Y___N___ <br />7.14.1 Two (2) adjustable shelves shall be provided in the D4 compartment. They <br />shall be easily adjusted to accommodate equipment/supply requirements. <br /> Y___N___ <br />7.14.2 One (1) adjustable shelf shall be provided in P-5 compartment fore of the <br />back board divider. <br /> Y___N___ <br /> <br />7.15 BACKBOARD DIVIDER <br /> <br />One (1) vertical, 55” x 17.5”x .125” smooth aluminum backboard divider shall be <br />through the inboard wall of Compartment P-5. It shall be positioned vertically 10"