Laserfiche WebLink
2.1 MEMBRANE <br /> <br />A. <br />perimeter, <br /> <br />B. Exposed decking shall be covered with two layers of No. 30 asphalt- <br />impregnated roofing felt. New roofing felt shall overlap existing a minimum of <br /> <br />2.2 FLASHING <br /> <br />A. Provide 20 oz. per square foot copper flashing for all valleys. Flashing shall <br />underlayment required in paragraph 2.1.B. <br /> <br />B. All pipe and vent penetrations shall have lead boots. <br /> <br />2.3 NAILS AND FASTENERS <br /> <br />A. Use only nails and fasteners approved by the manufacturer of the clay roofing <br />tiles used. <br /> <br />2.4 MORTAR <br /> <br />A. Provide a good grade mortar complying with recommendations of the <br />manufacturer of the clay roofing tiles used, and mixed with a suitable pigment <br />to produce a color matching the color of the approved roofing tiles. <br /> <br />2.5 ROOFING TILES <br /> <br />A. Provide Two-piece Italian Pan tiles and accessories to match existing. <br />1. Assume minimum 200 hip tiles for replacement. <br />2. Assume minimum 10 ridge tiles for replacement. <br />3. Assume 5 hip starters for replacement. <br />4. Assume minimum 20 eave closure pieces. <br />5. Field verify required field tile required for replacement before bids are <br />made to client. <br /> <br />2.6 CLEANER <br /> <br />A. Prosoco, Inc. EnviroKlean 2010 All Surface Cleaner. <br /> <br /> <br />2.7 OTHER MATERIALS <br /> <br />CLAY ROOFING TILES <br />07321-2 <br /> <br />