Laserfiche WebLink
the pump operator's panel. The valve operating mechanism shall indicate the position of the <br />valve. <br />If a handwheel control valve is used, the control shall be a minimum of a 3.9" diameter <br />chrome plated handwheel with a dial position indicator built in to the center of the <br />handwheel. <br />UGE RISER <br />3.00" deluge riser shall be installed above the pump in such a manner that a monitor can be <br />punted and used effectively. Piping shall be installed securely so no movement develops <br />ten the line is charged. The riser shall be gated and controlled at the pump operator's panel. <br />W WATER LEVEL ALARM <br />audible alarm shall be included that shall sound when the water level drops below one <br />ith of a tank. <br />CODING <br />ch discharge valve control, outlet, and corresponding gauge shall be color -coded. The <br />lor-coding shall be: <br />1 Discharge — To be determined in pre -build <br />2 Discharge — To be determined in pre -build <br />3 Discharge (Where applicable) — To be determined in pre -build <br />4 Discharge (Where applicable) - To be determined in pre -build <br />5 Discharge (Where applicable) - To be determined in pre build YES O <br />1 Speedlay Pre -Connect -To be determined in pre -build <br />2 Speedlay Pre -Connect - To be determined in pre -build <br />ront Bumper Line - To be determined in pre -build <br />arge Diameter Discharge — To be determined in pre -build <br />eft Hose Bed Pre -Connect - To be determined in pre -build <br />ight Hose Bed Pre -Connect - To be determined in pre -build <br />eft Rear Discharge - To be determined in pre -build ES O <br />ight Rear Discharge — To be determined in pre -build <br />leck Gun — To be determined in pre -build <br />filets — To be determined in pre -build <br />ank fill - To be determined in pre -build <br />ank to Pump — To be determined in pre -build <br />ELESCOPIC PIPING <br />The deluge riser piping shall include an 18.00" Task Force Model XG 18 Extend -A -Gun <br />extension. <br />This extension shall be telescopic to allow the deluge gun to be raised 18.00" increasing the <br />range of operation. <br />A position sensor shall be provided on the telescopic piping that shall activate the "do not <br />move vehicle" light inside the cab when the monitor is in the raised position. <br />A task force tips model monitor shall be properly installed on the deluge riser. <br />This monitor shall include both a fixed base and a portable base with a 5.00" Storz inlet. <br />The monitor shall be painted to match the body. <br />m <br />