Laserfiche WebLink
no more than three of a given species. <br />7. The use of non-native or exotic variants are not allowed on the project. <br />8. Deciduous trees of caliper greater than 2.5 inches at breast height may be used at the discretion of <br />the Contractor but will not affect the payment to the Contractor under the Pay Item. <br />9. Contractor shall warranty all trees for a period of two years from the date of planting. <br />10. Tree warranty includes replacement of any damaged or dead tree in the case of damage due to <br />frost, wind, heat stress, weather related damage and normal loss of the tree. <br />11. Trees replaced by the Contractor under the warranty will be of the same size and specimen of the <br />original tree. Dead or damaged tress shall be placed within a period no longer than 60 days from <br />the date of notification from the Owner to the Contractor. <br />12. If a tree is replaced under the warranty, that tree will be under warranty from the greater period of: <br />a. the time remaining from the initial 1-year warranty period <br />b. an additional 90-day warranty. <br />13. The Contractor is solely responsible for maintenance and care of trees during the warranty period. <br />14. Tree warranty shall be included in the Maintenance Bond. <br />15. Payment will be made under: <br />Pay Item Pay Unit <br />Plant, Deciduous Tree, Over 2 IN. to 2.5 IN. EACH <br />SP-46. REINFORCED CONCRETE BOX STRUCTURES <br />A. State Specifications: Section 714 <br />B. Additions: This Pay Item includes all work and materials to design and install the <br />proposed reinforced concrete box structure. <br />1. Three -sided structure substitution shall not be allowed for this project. <br />2. Concrete Headwalls, wingwalls and footings shall be designed by the Contractor in accordance <br />with 714.04 of the Standard Specifications. <br />3. Precast Concrete Headwalls, Wingwalls and Footing per Section 714.06. <br />4. The shop drawing submittal for the proposed structure footings, headwalls and wingwalls shall <br />meet the requirements of 714.04(b) and shall be certified by an engineer licensed to perform work <br />in the State of Indiana. <br />5. Reinforcing steel shall be coated at all installations providing less than two feet of cover. <br />6. Headwalls and wingwalls shall be of adequate length extent to avoid the need for slopes steeper <br />than 1.5 (Horizontal) to 1 (Vertical) at any location within the project. <br />7. Concrete Box Structure Joints shall be per 714.10. <br />8. Precast coated reinforced concrete box structures, precast headwalls, precast wingwalls, cast -in - <br />place headwalls, and cast -in -place wingwalls will not be measured. <br />9. The accepted quantities for payment will be the quantities shown on the plans. <br />10. The cost of headwalls and wingwalls shall be included in the out -to -out linear foot cost of the <br />Structure. <br />11. An 8" layer of coarse aggregate No. 8 is required below footings per Section 714.05. This <br />Version 7/01/2018 Special Provisions - 20 <br />