Laserfiche WebLink
2019 International MV/PL Custom Titan 170 <br />Type I Ambulance Proposal Specification <br />115 VOLT OUTLETS INTERIOR: <br />116 volt AC Duplex Electrical outlet shall be installed in the vehicle. The outlets shall be "Lighted" duplex type, The Neon <br />light within the outlet shall glow when live power is at the outlet. All outlets within the vehicle shall be GFI protected. The <br />location of the outlets shall be as follows, one (1) located on the back wall of the Life Support Station. <br />115 VOLT OUTLET INTERIOR: <br />115 volt AC Duplex Electrical outlet shall be installed in the vehicle. The outlets shall be "Lighted" hospital grade duplex <br />type. The Neon light within the outlet shall glow when live power is at the outlet. All outlets within the vehicle shall be <br />GFCI protected. The location of the outlet shall be as follows, one (1) located on the left rear wall of the vehicle. <br />I IS VOLT OUTLET INTERIOR: <br />I 15 volt AC Duplex Electrical outlet shall be installed in the vehicle, The outlets shall be "Lighted" hospital grade duplex <br />type. The Neon light within the outlet shall glow when live power is at the outlet. All outlets within the vehicle shall be <br />GFCI protected, The location of the outlet shall be as follows, one (1) located in the right front compartment. <br />115 VOLT OUTLET INTERIOR: <br />115 volt AC Duplex Electrical outlet shall be installed in the vehicle. The outlets shall be "Lighted" hospital grade duplex <br />type. The Neon light within the outlet shall glow when live power is at the outlet. All outlets within the vehicle shall be GA <br />protected. The location of the outlet shall be as follows, one (1) located in the right front upper compartment. <br />-'k,15 VOLT OUTLET INTERIOR: <br />115 volt AC Duplex Electrical outlet shall be installed in the vehicle. The outlets shall be Hospital Grade "Lighted" duplex <br />type. The Neon light within the outlet shall glow when live power is at the outlet. All outlets within the vehicle shall be GFI <br />protected, The location of the outlet shall be as follows, one (1) located on the wall above the aft area of the squad <br />bench. <br />BATTERY CHARGING EQUIPMENT <br />12 VOLT TO 115 VOLT INVERTER <br />1000T WATT INVERTER: <br />A Vanner Model 20-1050 CUL, 1050 watt inverter shall be installed in the rear electrical equipment cabinet of the vehicle. <br />The inverter shall have a built in transfer switch to power equipment from both the shoreline or vehicle power, The unit <br />shall also include a 55 amp battery charger built into the unit. <br />All battery leads to inverter shall be powered by a 2 GA SXL battery cable, minimum, directly from the battery side of the <br />vehicles master disconnect switch. <br />A4539-0001 <br />111-WIM&I <br />�*u <br />