2019 International MV/PL Custom Titan 170 <br />Type I Ambulance Proposal Specification <br />SEPARATE SWITCHES FOR OXYGEN COMPARTMENT <br />LIGHT <br />There shall be a separate, individual control switch in the vehicle to independently control the light within the oxygen <br />compartment. The switch shall be located in the Rear Main Switch Panel. <br />LSS LED PANEL LIGHT. <br />An indirect light located above the Life Support Station counter shall be used to illuminate the action area. The light shall <br />be a Heavy Duty LED panel light and be switched by a switch on the side of the light as well as from the rear main switch <br />panel. <br />SEPARATE SWITCH FOR PANEL LIGHT (LSS AREA) <br />There shall be a separate, individual control switch in the vehicle to independently control the Panel Light in the LSS area. <br />The switch shall be located in the Rear Main Switch Panel. <br />12 VOLT TECNIQ LED PATINET PROCEDURE LIGHTS: <br />The ceiling of the ambulance shall be equipped with two (2) TecNiq 42 LED light fixtures, mounted in the ceiling wire <br />raceway. The lights shall be located directly over the center position of the stretcher. The lights shall be controlled by a <br />separate relay controlled circuit and switch in the rear switch panel. <br />STEPWELL LIGHT: <br />independent, recessed LED step well light shall be provided in the rear side of the diamond plate step well and be <br />automatically activated whenever the side entrance door is open. The exterior shall be protected from weather and <br />damage. All connections shall be weatherproof, sealed connectors. <br />12 VOLT TECNIQ LED LIGHTS: <br />Four (4) 17", 42 LED fixtures shall be installed and equally spaced in between the (6) dome lights. The fixtures shall have <br />reinforced housings with a plastic diffuser which locks in place. The lights shall be relay controlled and switched by a <br />lighted single pole switch in the rear Life Support switch panel. All lights shall be mounted to the vehicle ceiling structural <br />members and not to the ceiling panel material alone. <br />RETANGULAR LIGHT; "CHECK OUT*'TIMER: <br />A 60 minute mechanical timer shall be provided at the side door of the vehicle to allow the Rectangular lig hts to be turned <br />to the on position when the vehicle exterior power source is connected and shall be powered by the vehicles 12 volt <br />battery charger. The lights shall be controlled by an additional transfer relay to prevent the lights from discharging the <br />vehicle batteries when the shoreline is not plugged in. The timer shall only function when the shoreline is plugged in, and <br />will not function when the battery switch is activated. <br />DUAL DOME LIGHT SWITCHES: <br />Per the requirements of KKK-A-1 822, two independent dome light circuits with two independent switches shall be <br />provided to control two banks of (3) dome lights each. The switches shall be marked in the Life Support panel as left <br />dome light and right dome light. Each switch shall power the low mode of the fixtures independently. <br />A4539-0001 08/24118 <br />45 <br />