My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Bids - Spec S - One or More 2018 or Newer Emergency Medical Vehicle - Crossroads Ambulance Sales & Service LLC - Part 2
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2018
>
Opening of Bids
>
Opening of Bids - Spec S - One or More 2018 or Newer Emergency Medical Vehicle - Crossroads Ambulance Sales & Service LLC - Part 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2025 11:48:54 AM
Creation date
8/30/2018 9:09:12 AM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
8/28/2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2019 International MV/PL Custom Titan 170 <br />Type I Ambulance Proposal Specification <br />12V AIR CONDITIONING CONDENSER: <br />The vehicle shall be equipped with a body 12 volt air conditioning condenser. The air conditioning condenser shall be <br />added to provide refrigerant cooling for the auxiliary compressor added for the body. The condenser shall be fan cooled <br />by a condenser mounted 12 volt cooling fan. The fan shall be relay controlled and only be activated when the rear air <br />conditioner unit is activated. The cooling rating of the condenser shall be 40,000 BTU, and the air flow rate shall be 2,800 <br />CFM. <br />DUCTED HEATER AND AIR CONDITIONING SYSTEM: <br />The unit shall have a minimum capacity of 38,000 BTU Air Conditioner and 60,000 BTU Heat operating with 12 volt <br />power, The unit will have a high performance 650 CFM Brushless blower fan with a five (5) year warranty. A receiver - <br />dryer shall also be installed on the evaporator case to remove moisture from the refrigerant system. The climate control <br />unit shall be permanently attached to the double ductwork system running full length of the ceiling of the vehicle. Each <br />duct shall be fully contoured with approximate dimensions of 5" wide and not protrude more than 2 3/4" from the ceiling. <br />In addition each duct shall have four (4) equally spaced from front to rear, fully adjustable 4-way adjustable louvers with <br />shut off feature at each register. The duct work shall be covered with a fully padded vinyl covering and incorporate the <br />vehicles drop down wire raceway cover in the center. The heater/air conditioner unit shall be located in the front of the <br />vehicle centered above the cab to body pass through. An air cleaner filter shall be installed in the return air grille located <br />in the underside of the cabinet. <br />The climate control unit shall include a twin air return system. One mounted high and one mounted low for full air re- <br />circulation. In addition the entire climate control unit shall be double insulated first by the standard body insulation and <br />secondly by a fully encompassing 5/16" thick reflective insulation. The reflective insulation shall also extend the full <br />length of the raceway duct, front wall and ceiling of the climate control cabinet. <br />All heater hoses provided shall be OEM style EPDM rubber type. The use of lesser quality hose or silicone hose is an <br />unacceptable substitution. The systems heater shall include an electric 2-way, internally piloted, normally closed solenoid <br />valve which only opens when the heater unit is "On" and when the vehicle is running, The heater shut off valve shall also <br />include an emergency shut off switch located within the rear power distribution panel. <br />All Air Conditioner hoses shall be Goodyear Galaxy Type 4890. Barrier type hose shall be unacceptable. <br />No exceptions or deviations to this system will be allowed due to its superior air distribution system and low noise <br />characteristics. An exception will be cause for rejection of bid. Bidderlmanufacturer must provide proof that this is an <br />operating climate control system, offered as a standard component in their emergency vehicle production. Prototype <br />systems are not acceptable, A user list of vehicles utilizing this system shall be provided with the bid. <br />ELECTRONIC DIGITAL DISPLAY THERMOSTAT <br />CONTROL: <br />A digital electronic Climate Control thermostat shall be used to monitor and control both air conditioning and heating in the <br />rear patient compartment. The following features are included: <br />A 1/2" backlit digital display, which displays both ambient and set temperatures. Ambient readout is displayed by <br />default. <br />Temperature adjustment is 500 F to 990 F or 100 C to 370 C, <br />Seven (7) fan speeds standard. Three (3) and Five (5) speed options also available. <br />The fan speed is easily controlled by using the color coded tactile up or down arrows. <br />A4539-0001 08/24/18 <br />43 <br />
The URL can be used to link to this page
Your browser does not support the video tag.