My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10072-11 Amend Code- Ch.21 Zoning, Article 12, Floodplain Regulations ref:10037-10
sbend
>
Public
>
Common Council
>
Legislation
>
Ordinances
>
2011
>
10072-11 Amend Code- Ch.21 Zoning, Article 12, Floodplain Regulations ref:10037-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2011 3:56:53 PM
Creation date
2/23/2011 3:56:52 PM
Metadata
Fields
Template:
City Council - City Clerk
City Council - Document Type
Ordinances
City Counci - Date
2/14/2011
Ord-Res Number
10072-11
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
21-12 (e) (2) (A) In addition to the requirements of Section 21-12 (e) (1), all structures to <br /> be located in the SFHA shall be protected from flood damage below the FPG. <br /> This building protection requirement applies to the following situations: <br /> i. Construction or placement of any new structure having a floor area greater than <br /> 400 square feet; or <br /> 21-12 (e) (2) (B) Residential Construction. New construction or substantial improvement <br /> of any residential structure (or manufactured home) shall have the lowest floor; <br /> including basement, at or above the FPG (two feet above the base flood <br /> elevation). Should solid foundation perimeter walls be used to elevate a structure, <br /> openings sufficient to facilitate the unimpeded movements of floodwaters shall be <br /> provided in accordance with the standards of Section 21-12 (e) (2) (D). <br /> 21-12 (e) (2) (C) Non-Residential Construction. New construction or substantial <br /> improvement of any commercial, industrial, or non-residential structure (or <br /> manufactured home) shall either have the lowest floor, including basement, <br /> elevated to or above the FPG (two feet above the base flood elevation) or be <br /> floodproofed to or above the FPG. Should solid foundation perimeter walls be <br /> used to elevate a structure, openings sufficient to facilitate the unimpeded <br /> movements of floodwaters shall be provided in accordance with the standards of <br /> Section 21-12 (e) (2) (D). Structures located in all "A Zones" may be <br /> floodproofed in lieu of being elevated if done in accordance with the following: <br /> i. A Registered Professional Engineer or Architect shall certify that the <br /> structure has been designed so that below the FPG, the structure and <br /> attendant utility facilities are watertight and capable of resisting the effects <br /> of the regulatory flood. The structure design shall take into account flood <br /> velocities, duration, rate of rise, hydrostatic pressures, and impacts from <br /> debris or ice. Such certification shall be provided to the official as set forth <br /> in Section 21-12 (d) (3) (J). <br /> 21-12 (e) (2) (D) Elevated Structures. New construction or substantial improvements of <br /> elevated structures shall have the lowest floor at or above the FPG. <br /> Elevated structures with fully enclosed areas formed by foundation and other <br /> exterior walls below the flood protection grade (crawlspaces or under floor <br /> spaces) shall be designed to preclude finished living space and designed to allow <br /> for the entry and exit of floodwaters to automatically equalize hydrostatic flood <br /> forces on exterior walls. Designs�°^ „'�,:��• ,:*'� *'�:� r �*must°�� <br /> ��-ee�€re�-b}�--ft-��e€e�ss�e�-e�g�eer--er--�c�i��ec�-s� meet the following <br /> minimum criteria: <br /> i. provide a minimum of two openings located in a minimum of two exterior <br /> walls �having a total net area of not less than one square inch for every one <br /> square foot of enclosed area; and <br /> Page 3 of 6 <br />