My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PSA - Data Realty Northern Indiana
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2016
>
Agreements, Contracts, Proposals, and Addenda
>
PSA - Data Realty Northern Indiana
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2025 1:12:26 PM
Creation date
11/9/2016 1:54:02 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Contracts
Document Date
11/8/2016
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
IV. Fire Suppression — The data center space is protected by an inert gas <br />fire protection system. Installation of FM-200 within raised floor area, <br />pre -action within Mechanical, Electrical & Plumbing areas. <br />V. Monitoring — DRNI shall provide continuous monitoring of all critical <br />support equipment via both electronic and human means. Sensors will <br />be installed to monitor ambient temperature, humidity and to provide <br />leak detection, and the data center will be staffed 24x7x365. <br />vi. UPS — Designed as a Distributed Catcher system transferring load at the <br />PDU level. Each UPS output distribution panel serves individual branch <br />circuit panel boards to furnish "A" and "B" redundant branch circuit UPS <br />power capabilities to each Customer cabinet. The power circuits are <br />arranged so that one (1) circuit is providing conditioned power to <br />Customer's cabinet from UPS-1 and the other circuit is providing <br />conditioned power from UPS-2. Customer must install equipment <br />which allows for dual power supplies. It is the Customer's responsibility <br />to connect appropriately. Custom power delivery systems can be <br />designed on a per Customer basis. <br />vii. Telecommunications — DRNI provides a carrier neutral facility with <br />diverse entry points, dual meet -me -rooms and copper or fiber cross <br />connected as requested by Customer. Multiple fiber carriers are <br />available. Selection and configuration of network services is <br />responsibility of Customer. DRNI can provide contact information for <br />several carriers who provide Internet and/or private bandwidth services <br />at the DRNI data center. Customer is responsible for selection and <br />configuration of all external network services which may be required <br />including any required equipment, software, or implementation <br />services. Fiber hand-offs use Single Mode Fiber. <br />viii. Generators — Two 1500kW generators equipped with dedicated sub- <br />base fuel tanks, fully redundant starting and charging systems, and fuel <br />monitoring and scrubbing systems are located on site. Fuel storage is <br />maintained to provide a minimum 48-hour run time, with contracted <br />refill schedules with redundant carriers. The generators will be load <br />tested regularly. <br />ix. HVAC — DRNI utilizes eight (8) 40 ton CRAH Units installed within each <br />CRAH gallery for cooling supported by a water -based system fed from a <br />redundant chiller system. CRAH units are provided with dual electrical <br />sources with integral automatic transfer switches. Ambient air is <br />utilized in the cooling process to lower cooling costs and increase <br />efficiency. DRNI will maintain cooling capacity with a minimum of (N <br />+1) redundancy on all systems. One (1) redundant CRAH for every three <br />(3) required for capacity. UPS rooms are each supported by (2) <br />dedicated and redundant 6-ton CRAH Units with independent water <br />feeds <br />DRNI Co -Location Schedule Page 2 of Revised August 26,2016 <br />