My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PSA - Data Realty Northern Indiana
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2016
>
Agreements, Contracts, Proposals, and Addenda
>
PSA - Data Realty Northern Indiana
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2025 1:12:26 PM
Creation date
11/9/2016 1:54:02 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Contracts
Document Date
11/8/2016
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SCHEDULE [A] <br />to <br />MASTER SERVICES AGREEMENT <br />between <br />Data Realty Northern Indiana, LLC. <br />("DRNI") <br />and <br />City of South Bend <br />("Customer") <br />1. Reference to Agreements. This Exhibit is executed pursuant to the Master <br />Services Agreement dated October 2016 ("Agreement"), executed by the undersigned, and <br />shall be deemed to be a part thereof. <br />2. Description of Services. DRNI will provide Data Center Services to Customer. The <br />following details the services ("Services") to be provided under this Schedule: <br />a) Data Center Space The data center space will be used by Customer to co -locate <br />server, storage, and network cabinets. <br />The data center space has the following characteristics: <br />i. Security — Security is provided using biometric hand scanners for <br />authorized access. CCTV - state of the art video surveillance is installed <br />at each entrance, around the external facility, and in all data and core <br />infrastructure rooms. Security desk performs 24x7 monitoring. There is <br />a secure fenced area around generators and cooling towers. Security <br />Systems are powered by a redundant UPS infrastructure. <br />ii. Cooling — The facility has two (2) chilled water systems with an initial <br />redundant mechanical load capacity of 250 Tons and an overall capacity <br />of 750 Tons for initial building. Chiller Plant is an N+1 design with a <br />single pathway and will provide process cooling for the space. These <br />systems shall maintain proper temperature and humidity levels for <br />appropriate equipment operation using a closed -loop high -efficiency <br />chiller system. Chillers are magnetic bearing / oil free, with evaporative <br />condensers. The chilled water systems are designed to operate twenty- <br />four (24) hours per day, three -hundred sixty-five (365) days per year. <br />The systems are designed to allow for individual unit maintenance <br />and/or replacement without affecting the overall cooling of the space. <br />iii. The average temperature and humidity will be maintained at levels in <br />accordance with published ASHRAE TC9.9 Data Center Standards. If <br />ASHRAE standards change Data Realty will maintain compliance with <br />current standards. <br />DRNI Co -Location Schedule Page 1 of Revised August 26, 2016 <br />
The URL can be used to link to this page
Your browser does not support the video tag.