Laserfiche WebLink
ATTACHMENT B <br />South Bend Cellular Communications Schedule <br />55 locations <br />Rev date: 6/3/16 <br />This equipment schedule identifies the Gnode and Inode units covered by the Agreement between <br />the Owner of South Bend and EmNet, LLC. <br />The listed Gnodes have cellular communication and are needed for logging sensor information. <br />No. <br />Noe <br />Purpose <br />Location <br />New? <br />1 <br />G.1.2 <br />CSO control site <br />CSO 44 Northview and Riverside <br />No <br />2 <br />G.1.1 <br />CSO outfall monitoring <br />CSO I Oakwood and Riverside <br />No <br />3 <br />G.2.1 <br />Trunkline Monitoring <br />Hamilton and Portage <br />No <br />4 <br />G3a.1 <br />CSO outfall monitoring and control <br />CSO 3 Sherman and Riverside <br />No <br />5 <br />G.3b.1 <br />CSO control site <br />CSO 4, Riverside and Angela <br />No <br />6 <br />GAT <br />Trunkline Monitoring <br />Bendix and Westmont <br />No <br />7 <br />G.5.1 <br />Trunkline Monitoring <br />Orange and Olive <br />No <br />8 <br />G.6.1 <br />Trunkline Monitoring <br />Sheridan and Sample <br />No <br />9 <br />G.8.1 <br />CSO Outfall monitoring <br />River Crossing 94 Riverside and Lafayette <br />No <br />10 <br />L8 2 <br />CSO control site <br />CSO 25 Lafayette and North Shore <br />No <br />I <br />G.9.1 <br />CSO outfall monitoring <br />North Shore and Michigan <br />No <br />12 <br />G.10.1 <br />CSO outfall monitoring and control <br />CSO 27/28 Niles and Sorin <br />No <br />13 <br />G.1I.1 <br />CSO monitoring <br />CSO 29 Lift Station, Cabinet 2 <br />No <br />14 <br />G. 12.1 <br />Trunkline Monitoring <br />Michigan and South <br />No <br />15 <br />G.13.1 <br />CSO outfall monitoring <br />Monroe and Edgewater <br />No <br />16 <br />1.13.1 <br />CSO control site <br />CSO 14, Monroe and LWE <br />No <br />17 <br />G. 14.1 <br />Trunkline Monitoring <br />Calvert and Miami <br />No <br />18 <br />G. 15.1 <br />CSO outfall monitoring <br />CSO 22 East End Trunk Sewer <br />No <br />19 <br />G. 16.1 <br />Trunkline Monitoring <br />Miami and Ridgedale <br />No <br />20 <br />G.17.1 <br />Trunkline Monitoring <br />Chippewa and Main <br />No <br />21 <br />G. 18.1 <br />Basin Momtoring/Control <br />Ireland Miami Basin <br />No <br />22 <br />G.19.1 <br />Basin Monitoring/Control <br />York and Provincial <br />No <br />23 <br />G.20.1 <br />Trunkline Monitoring <br />Mishawaka and Logan <br />No <br />24 <br />G.21.1 <br />CSO outfall monitoring <br />CSO 39 27th St. Lift Station <br />No <br />25 <br />G.22.1 <br />Trunkline Monitoring <br />Twyckenham and Mishawaka <br />No <br />26 <br />G.23.1 <br />Trunkline. Monitoring <br />Twyckenham and Mishawaka <br />No <br />27 <br />G.24.1 <br />CSO outfall monitoring <br />CSO 33 Emerson and Northside <br />No <br />28 <br />G.26.1 <br />Trunkline Monitoring <br />McKinley and Ironwood <br />No <br />29 <br />G.28.1 <br />Basin Monitoring/Control <br />Corby and Hickory <br />No <br />30 <br />G.29.1 <br />CSO outfall monitoring <br />CSO 6 Leland and Riverside <br />No <br />EJCDC E-520 Short Form of Agreement Between Owner and Engineer for Professional Services. <br />Copyright ©2009 National Society of Professional Engineers for EJCDC. All rights reserved. <br />Page 17 <br />