My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Award Quote - Locust Water Booster Pump Improv Proj No 124-058 - Engineered Solutions
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2024
>
Award Quotations & Proposals
>
Award Quote - Locust Water Booster Pump Improv Proj No 124-058 - Engineered Solutions
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 9:29:45 AM
Creation date
11/26/2024 1:42:08 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
11/26/2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Technical specifications <br />connection <br />Voltage and power range <br />Input voltage (1.13) <br />ACQ580-01-xxxA-2 <br />208-240 V <br />AC0580-01-xxxA-4 <br />440-480 V <br />ACQ580-01-xxxA-6 <br />525-600 V <br />Input voltage tolerance _ <br />10%/-15% <br />Line Limitations <br />Max±3% of nominal phase to <br />phase input voltage_ <br />Power Factor (cos (D) at nominal load <br />- - <br />ACQ580-01 <br />I --_ - <br />Efficiencyatat rated power <br />ACQ580-01 <br />98% <br />Power Loss <br />Approximately 2-3%of rated <br />Motor connection <br />Supported motor control <br />Scalar and vector <br />Supported motor types <br />Asynchronous motor, <br />permanent magnet motor <br />_ <br />(vector), SynRM (vector) <br />Voltage <br />3-phase, from 0 to supply <br />__. <br />voltage_ <br />Frequency _ <br />_ <br />0 to 500 Hz <br />ShortTerm Overload Capacity <br />_ <br />110%for 1 min/10min <br />Variable Torque <br />Peak Overload Capacity <br />1.35 for 2 second <br />Variable Torque <br />(2 sec /l minute) <br />Switching Frequency <br />2, 4, 8 or 12 kHz (Up to 150 Hp); <br />1 or 4 kHz (Over 150 Hp), <br />Automatic fold back in case <br />of overload <br />Acceleration/Deceleration Time <br />0 to 1800 s <br />_ <br />Short Circuit Current Rating <br />100 kA (UL) with fusing <br />External power supply <br />ACQ580-01, R6-R9: Standard <br />1.50 A at 24 V AC/DC <br />t10%/36W <br />ACQ580-01, R1-R5: Optional card <br />1.04 A at 24 V AC/DC <br />±10%/ 25W <br />Safety <br />Safe Torque Off (STO) <br />STO Standard Input <br />17 .30 VDC, 55MA <br />Degree of Protection <br />Degree of protection (IEC/EN 60529) <br />ACO580-01 <br />IP21, IP55 <br />Enclosure types (1.11-508C/61800-5-i) <br />ACQ580-OS <br />UL (NEMA) Type 1 & 12 <br />Inputs and outputs <br />2 analog inputs <br />Selection of Current/Voltage Input <br />mode is user programmable. <br />Voltage reference _ _ _ <br />0 (2) to 10 V, Rin > 200 k0 <br />Current reference <br />0 (4) to 20 mA, Rin =100 0 <br />Potentiometer reference <br />10 V ±1% Max. 20 MA <br />value <br />2 analog outputs <br />AO1 Is user programmable, for <br />current or voltage. AO2 current <br />Voltage reference <br />0 to 10 V, Riwa: > 100 kO <br />Current reference <br />0 to 20 MA, Ri.: <500 0 <br />Applicable potentiometer_ <br />_ <br />1 k0 to 10 kO <br />Internal auxiliary voltage <br />24 V DC±10%, max. 250 MA <br />Accuracy <br />+/-1%full scale range at 25°C <br />(77-F) <br />Output updating time <br />2 ms <br />6 digital inputs <br />12 to 24 V DC, 10 to 24 V AC, <br />Connectivity of PTC sensors <br />supported by a single digital input. <br />PNP or NPN connection <br />(5 Dls with NPN connection). <br />Programmable <br />Input Updating Time <br />2 ms <br />3 relay outputs <br />Maximum switching voltage <br />250 V AC/30 V DC. <br />Maximum continuous current 2 A <br />Mrs. <br />Programmable, Form C <br />Contact material <br />_ <br />Silver Tin Oxide (AgSnoz) <br />PTC, PT100 and PT3000 <br />Any of the analog Inputs, or digital <br />input 6, are configurable for PTC <br />with up to 6 sensors. <br />Adjustable filters on analog <br />inputs and outputs <br />All control Inputs Isolated from ground and power <br />Operation <br />Air Temperature <br />-15 to+40°C(5 to 104 OF) <br />50-C (122^F) available with derate <br />0 to -15 °C (32 to 5 OF) <br />No Frost Allowed <br />Output derated above +40°C <br />(104°F) <br />Installation site Altitude <br />0 to 1000 m (3281 ft) above sea <br />level <br />Output derated above <br />1000m (3281 it) up to 4000m <br />(13123ft) <br />Relative Humidity <br />5 to 95% <br />No condensation allowed <br />Maximum relative humidity Is 6091 <br />in the presence of corrosive gasses <br />Atmospheric pressure <br />70 to 106 kPa (101 to 15.4 PSI) <br />0.7 to_1.05 atmospheres <br />Vibration <br />Risk category IV Certified (IBC <br />
The URL can be used to link to this page
Your browser does not support the video tag.