Laserfiche WebLink
PIERCE MANUFACTURING INC.° <br />AN OSHKOSH TRUCK CORPORATION® COMPANY <br />Certification Document CDO130 <br />Saber° FR - Enforcer TM <br />Cab Integrity Certification <br />Pierce Manufacturing certifies the integrity of the Saber° FR — EnforcerTM cab relative to <br />occupant protection. <br />A specimen representing the substantial structural configuration of the Saber° FR — EnforcerTM <br />cab models has been successfully tested in accordance with the following standards. <br />• SAE J2422 Cab Roof Strength Evaluation — Quasi -Static Loading Heavy Trucks. <br />• European Occupant Protection Standard ECE Regulation No. 29. <br />• SAE J2420 COE Frontal Strength Evaluation — Dynamic Loading Heavy Trucks. <br />Side Impact: The test cab was subjected to dynamic preload <br />where a 14,253 lb moving barrier was slammed into the side of <br />the cab at 5.25 mph, striking with an impact of 13,000 ft-Ibs of <br />energy. This test is not required to meet the ECE 29 standard, <br />but is part of the SAE J2422 test procedure and more closely <br />represents the forces a cab will see in a roll-over incident. <br />Frontal Impact: The test cab was struck by the 14,253 lb moving <br />barrier at a speed sufficient to impart the required 32,549 ft-Ibs of <br />energy. <br />CD0130 Cab Integrity Certification - Saber FR - Enforcer .doc 1 11/17/2014 <br />