Laserfiche WebLink
• Five (5) fluorescent orange traffic cones not less than 28.00" (711 mm) in height, each equipped <br />with a 6.00" (152 mm) retro-reflective white band no more than 4.00" (152 mm) from the top of <br />the cone, and an additional 4.00" (102 mm) retro-reflective white band 2.00" (51 mm) below the <br />6.00" (152 mm) band. <br />• Five (5) illuminated warning devices such as highway flares, unless the five (5) fluorescent <br />orange traffic cones have illuminating capabilities. <br />• One (1) automatic external defibrillator (AED). <br />• Four (4) ladder belts meeting the requirements of NFPA 1983, Standard on Fire Service Life <br />Safety Rope and System Components (if equipped with an aerial device). <br />v If the supply hose carried does not use sexless couplings, an additional double female adapter <br />and double male adapter, sized to fit the supply hose carried, will be carried mounted in <br />brackets fastened to the apparatus. <br />• If none of the pump intakes are valved, a hose appliance that is equipped with one or more <br />gated intakes with female swivel connection(s) compatible with the supply hose used on one <br />side and a swivel connection with pump intake threads on the other side will be carried. Any <br />intake connection larger than 3.00" (75 mm) will include a pressure relief device that meets the <br />requirements of 16.6.6. <br />• If the apparatus does not have a 2.50" National Hose (NH) intake, an adapter from 2.50" NH <br />female to a pump intake will be carried, mounted in a bracket fastened to the apparatus if not <br />already mounted directly to the intake. <br />• If the supply hose carried has other than 2.50" National Hose (NH) threads, adapters will be <br />carried to allow feeding the supply hose from a 2.50" NH thread male discharge and to allow the <br />hose to connect to a 2.50" NH female intake, mounted in brackets fastened to the apparatus if <br />not already mounted directly to the discharge or intake. <br />SOFT SUCTION HOSE PROVIDED BY FIRE DEPARTMENT <br />NFPA 1901, 2016 edition, section 5.8.2.1 requires a minimum of 20' of suction hose or 15' of supply <br />hose will be carried. <br />Hose is not on the apparatus as manufactured. The fire department will provide suction or supply hose. <br />DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT <br />NFPA 1901, 2016 edition, section 5.9.4 requires one (1) approved dry chemical portable fire <br />extinguisher with a minimum 80-B:C rating mounted in a bracket fastened to the apparatus. <br />The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount <br />the extinguisher. <br />WATER EXTINGUISHER PROVIDED BY FIRE DEPARTMENT <br />NFPA 1901, 2016 edition, section 5.9.4 requires one (1) 2.5 gallon or larger water extinguisher <br />mounted in a bracket fastened to the apparatus. <br />The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount <br />the extinguisher. <br />78 of 89 <br />