Laserfiche WebLink
PRESERVATION SPECIALIST REPORT: <br />Excerpt from February 16, 2017 LOAM Steve Szaday <br />I am familiar with this property as I had personally on my own time helped the owner secure the property after <br />multiple break-ins over the last four years. Many of the boarding that had taken place prior to my involvement especially those <br />done on the second level utilized poorly fitting boards that allowed elements to enter at the top and settle on the window sashes <br />and sills. Luckily, there are storm windows on most of the windows. Most of those had been broken instead of the actual sash <br />glass. I counted ten storms with broken glass and six sashes with broken or missing glass. The structure has been without <br />permanent occupants or heat since the 1980s. Fortunately, the roof that was in place had no leaks and only minor water damage <br />in the plaster on second floor corners as a result of failing gutters. <br />The end result of my inspection is that one in three windows are in sound condition and not deteriorated beyond <br />repair. Those windows had properly fitted boarding and intact storms. They are all however, painted shut and without weight <br />ropes. The remainder have suffered severe structural damage and dry rot as a result of having elements enter but not having <br />anywhere to exit. The most damage is to the sashes and the sills. The side framework is structurally sound other than in those <br />areas where damage was sustained during break-ins. <br />The large fixed picture window in the front is broken with a large hole. (the glass is '/4" thick and has a green hue) The <br />iconic oval window on the west side needs some frame attention but is in good shape. The windows located at the rear "mud - <br />room" addition have had most of the frame work broken out and currently have either plate glass or plexiglass in place. <br />Excerpt from June 19, 2017 9AM Steve Szaday <br />I photographed each window on second and first floors and there are 14 windows that he is looking to replace. The <br />structure has been boarded up for decades with the exception of six windows. This has helped the longevity of some windows <br />but has caused some damage to others where the boarding was improperly sized or installed. <br />I will break this down into groups based upon their condition: <br />(1) One window is completely gone and is merely a plexiglass non operable storm window <br />(2) Three windows have sturdy sashes that merely need re -roping and paint removal, however they are spread out <br />throughout the house. <br />(3) One window is the oval window that is completely deteriorated. The framework is dry -rotted and in places missing. <br />The glass is intact but not original as it is thinner than the other window panes in the house. <br />(4) Four windows have sashes that are in need of repairs but are salvageable. These windows were not boarded properly <br />but were sized short of the top allowing elements in and to be trapped. In addition, a galvanized sill wrap was installed <br />but not caulked. Water infiltration has seeped around the galvanized metal and has rotted out the sills and bottom <br />plate. I can apply pressure to the sill and have sponge -like movement. The interior plaster shows water damage off <br />the lower comers that runs to the base board trim. <br />(5) Three windows have structural damage due to abuse and vandalism(break-ins). These sashes could be repaired but <br />parting and interior stops are missing or broken and will need to be replaced <br />(6) One window has an upper sash that is painted in place and appears to be in good condition but is missing the lower <br />sash. <br />(7) One windows is a large picture window at front of house. This window is a single pane sash with 1/8" thick glass that <br />is broken. The glass measures approximately 74" inches wide by 50" inches tall. The sash is in good condition with <br />the exception of a piece of the interior which is broken at the point where the glass was broken from the outside. <br />The only intact storm window is the non-operable one where there is no sashes left inside. None of the remaining storm <br />windows are complete and will all need to be replaced, I did not find any screens. <br />STANDARDS AND GUIDELINES: <br />Chapin Park <br />THE ENVIRONMENT <br />A. THE DISTRICT ENVIRONMENT <br />The Chapin Park Local Historic District is a particularly fine residential area located close to downtown South Bend, the St. Joseph River, <br />Memorial Hospital and Leeper Park. This section is meant to protect and guide appropriate maintenance of the common areas of the district <br />(i.e. visual landscape and streetscapes) <br />Required <br />Brick streets contribute greatly to the character of the neighborhood. These streets have always been essentially passenger car thoroughfares. <br />The appointments of the streets (i.e. lighting, curbs, horse hitches and monuments) should contribute as much as possible to their architectural, <br />historic, and residential character. <br />Retention and maintenance of existing brick streets in the district is required. Repair work to fill voids and gaps must utilize brick paver <br />materials and acceptable installation methods whenever applicable. When utility work dictates the removal of street sections (pavers), the <br />original materials will be reinstalled. Brick streets shall be patched with brick pavers. Concrete, asphalt, fillers, and similar materials shall not <br />be used. <br />All original streetlights shall be maintained, especially the George Cutter "Park View" streetlights designed by the Cutter Company for this <br />neighborhood. Present efforts by the Neighborhood <br />Association and the Historic Preservation Commission to restore "Park View" streetlights to the district shall continue. Any change in lighting <br />must receive approval of the Historic Preservation Commission. <br />