Change Order No. 1 - Calvert Street Lift Station Replacement Proj No 116-053 - HRP Construction, Inc.
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2017
>
Change Orders
>
Change Order No. 1 - Calvert Street Lift Station Replacement Proj No 116-053 - HRP Construction, Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/31/2025 2:35:40 PM
Creation date
5/24/2017 1:23:30 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
5/23/2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Joe Sag ars <br />From: Joe Saggars <br />Sent: Thursday, March 2, 2017 10:05 AM <br />To; Joe Saggars <br />Subject: RE: Change order request for permanent power <br />Jacob, <br />Please see r•espames below in red and C APITAL IZED text, <br />Thanks, <br />00 <br />HRP Construction <br />From: Jacob Klosinski (mailto:iklosinsta southbendin.aov7 <br />Sent: Thursday, February 23, 2017 8:34 AM <br />To: Joe Saggars <br />Cc: Anthony Kenning (akenninga dlz.com) <br />Subject: RE: Change order request for permanent power <br />Joe: <br />Please ask Michiana Contracting, Inc. to provide the breakdown of Material, Labor, Rental Costs, and catalog <br />out sheets for the proposed items listed in the proposal. SEE ATTACHED. <br />Has AEP explained the need for two (2) four inch conduits? Are both being used or are they proposing one to <br />be provided as a spare? The City does not need to install a spare if the conduit is not being utilized for the <br />power feed by AEP for the Lift Station. ONE IS INDEED A SPARE, BUT AEP IS REQUIRING IT. SEE <br />ATTACHED. <br />What is the credit associated with the 1-1/4" Conduit Raceway material that is not being run in lieu of the 4" <br />conduits for the power feed (Refer to Sheets E0.1, E1.0, E2.0)? This is not described in the change order <br />proposal. THIS WAS OMITTED FROM THE FIRST PRICING BREAKDOWN, PLEASE SEE ATTACHED <br />CREDIT. <br />Why does this equipment require a separate H-Frame? Why can't tie equipment be mounted to the proposed <br />utility pole using U-bolts, Uni-strut and a Back Plate? This would be much more cost effective for the <br />City. PLEASE SEE ATTACHED DLZ RESPONSE TO RR #10 REQUIRING WHAT HAS BEEN <br />SUBMTTED. THE COMBINATION OF ITEMS TO BE MOUNTED TO THE POLE WOULD BE TOO WIDE TO <br />ONLY HAVE ONE VERTICAL UPRIGHT. ALSO, THAT WOULD NOT MEET AEFS REQUIREMENTS OF <br />TWO VERTICAL UPRIGHTS. <br />Regards, <br />Jacob <br />