Laserfiche WebLink
-16- <br />soil and waste stacks, mains and branches, fifty (50) square <br />feet of roof or yard area in horizontal projection shall <br />count as one fixture. <br />Three feet of urinal trough or wash sink shall count <br />as one fixture. <br />One bath, basin or sink or smaller fixture shall count <br />as one fixture. <br />One water closet shall count as four fixtures. <br />Section LIII. Special requirements. When the rain- <br />water drain connects inside of the building, it shall be of <br />the same material as a soil drain, and when passing up to <br />roof within a building it shall be tested the same as the <br />soil system with the water test, in which case the rainwater <br />trap may be omitted. <br />Section LIV. If rainwater drain connects to the main <br />MAXIMUM NUMBER OF <br />FIXTURES CONNECTED TO <br />Waste <br />Soil and Waste -- Combine <br />Soil Pipe <br />Alone <br />Size of Pipe <br />Branch <br />Main <br />Branch <br />Main <br />Fixtures <br />Fixtures <br />Water <br />Water <br />Closets <br />Closets <br />1 <br />� <br />inch <br />1 <br />12 <br />inch <br />1 <br />2 <br />2 <br />inch <br />2 <br />4 <br />22 <br />inch <br />3 <br />5 <br />3 <br />inch <br />5 <br />10 <br />32 <br />inch <br />10 <br />20 <br />4 <br />inch <br />24 <br />48 <br />6 <br />12 <br />5 <br />inch <br />72 <br />144 <br />18 <br />36 <br />6 <br />inch <br />96 <br />192 <br />24 <br />48 <br />7 <br />inch <br />240 <br />480 <br />60 <br />120 <br />8 <br />inch <br />400 <br />800 <br />100 <br />200 <br />9 <br />inch <br />580 <br />1160 <br />145 <br />290 <br />10 <br />inch <br />800 <br />1600 <br />200 <br />400 <br />11 <br />inch <br />1060 <br />2120 <br />265 <br />530 <br />12 <br />inch <br />1420 <br />2840 <br />355 <br />710 <br />Providing that <br />the number of water closets <br />on any soil <br />pipe, with or without <br />other <br />fixtures, shall <br />never exceed the <br />number given in <br />either of the last two columns. <br />The number <br />of fixtures <br />in a building <br />shall determine the <br />size <br />of the house <br />drain and <br />the combined area of the <br />soil or <br />waste.stacks <br />shall <br />in no case be less than <br />that the area of <br />the <br />house drain. <br />Section LIII. Special requirements. When the rain- <br />water drain connects inside of the building, it shall be of <br />the same material as a soil drain, and when passing up to <br />roof within a building it shall be tested the same as the <br />soil system with the water test, in which case the rainwater <br />trap may be omitted. <br />Section LIV. If rainwater drain connects to the main <br />