Laserfiche WebLink
Pre-Qualification Definition Pre-qualification Requirements <br /> Category <br /> certification <br /> Special Those contractors who are able to Equipment: <br /> perform repair work under the • Trench box system to <br /> following conditions: provide trench safety per <br /> • Dewatering(any depth) OSHA for depths greater <br /> • Open cut excavation greater than eight feet at a trench <br /> than nine feet deep width of four feet(outside <br /> width) <br /> • Excavator able to support <br /> excavation depths deeper <br /> than eight feet with a trench <br /> width no greater than four <br /> feet. <br /> Experience: <br /> Demonstrate experience through <br /> reference for any special <br /> considerations or conditions <br /> Safety: <br /> OSHA confined space training <br /> certification <br /> OSHA competent person training <br /> certification <br /> iii. A contractor may be pre-qualified for any combination of the categories within the Registry. <br /> iv. The Sewer Insurance Administrator reserves the right to utilize a contractor not pre-qualified <br /> on the Registry on a conditional basis for demonstration of new technologies or techniques. <br /> Any deviation from the Registry on the part of the Sewer Insurance Administrator shall be <br /> reported to the Board at the earliest convenience of the Board. <br /> V. A contractor shall have one of the two following pre-qualified conditions assigned by the <br /> Sewer Insurance Administrator: <br /> (1).Fully pre-qualified: This condition indicates that the Sewer Insurance Administrator has <br /> determined that a contractor has demonstrated through actual work, technical skill, <br /> equipment on hand, or references that they have the capability to perform the work <br /> required for the pre-qualification category in question. <br /> (2).Probationary pre-qualified: This condition indicates that the Sewer Insurance <br /> Administrator has determined that the contractor has met one of the following situations: <br /> (a) The contractor has not demonstrated technical qualifications to the complete <br /> satisfaction of the Sewer Insurance Administrator, and is being placed on the <br /> Registry provisionally; or <br /> (b) The contractor's success rate in repair of a Private Sewer over a rotating six <br /> month basis has dropped below 75%; or <br /> (c) The contractor was fully pre-qualified, but has not demonstrated the technical <br /> competence claimed on the pre-qualification form provided. <br /> 6 <br />