Laserfiche WebLink
Emissions & Particulate Matter Testing <br />Human Remains and Pet Cremators <br />Armil /CFS Reference Number CFS2300 /CFSPet <br />May 18, 2010 Revision 1 <br />Calibration of the testing equipment was performed pre -test and post -test. Specific information <br />regarding the equipment, procedures, and N.I.S.T. traceability are available upon request, from <br />Armil /CFS Incorporated (708) 339 -6810. <br />SUMMARY OF RESULTS Average of three (3) test runs <br />Calibration Corrected Test Data <br />Filterable Particulate (PM): 0.050 lb/hr <br />0.021 grains /scf @ 12% CO2 <br />Filterable PM determination by USEPA method 5 <br />02 (oxygen) 6.2 % dry <br />Oxygen determination by Method 3A, 40CFR60 <br />CO2 (carbon dioxide) 11.8 % dry <br />Carbon Dioxide determination by Method 3A, 40CFR60 . <br />CO (carbon monoxide) 0.02 lb/hr <br />13.8 ppm @ 50% excess air <br />Carbon Monoxide determination by Method 10, 40CFR60 <br />EXTRAPOLATION OF RESULTS (Particulate Matter) Stack Emission, CFS -2300 <br />Estimated daily and annual stack emission totals based on normal cremator operation. <br />PM Daily: 10 hrs x 0.050 lb/hr 0.5 lbs per day <br />PM Annually: 5 days/ week x 52 weeks 130 lbs per year <br />EXTRAPOLATION OF RESULTS (Particulate Matter) Stack Emission, CFS -Pet <br />Estimated daily and annual stack emission totals based on normal cremator operation. <br />PM Daily: 10 hrs x 0.033 lb /hr 0.33 lbs per day <br />PM Annually: 5 days/ week x 52 weeks 86 lbs per year <br />Data compiled by: <br />Armil /CFS Engineering Department <br />Page 2 of 2 <br />