Friday, December 5, 2025 Quote #: 8393124 FARS - The Monarch - South Bend IN <br /> <br />Page 3 of 7 <br />- 120V Fire Input x1 <br />- CFM monitoring for MUA units. Uses rivet nuts, 1/4" airflow tubing and push to connect fittings. x1 <br />- Overheat Stat factory set at 80°F and 10 minutes. Prevents unit from overheating the space when <br />cooling. <br /> x1 <br />- Discharge Firestat. Set to 240°F x1 <br />- Intake Firestat. Set to 135°F x1 <br />- Freezestat x1 <br />- Blower Delay Stop. Allows supply fan to run after the burner has shut off Factory set at 90 secs for <br />indirect 30 secs for direct. <br /> x1 <br />- i51BP215D0000ACBSS - i500 Variable Frequency Drive - 2 HP Max., 230 V, 1Ph or 3Ph, 7 A Max., <br />NEMA 1 Enclosure, PART NEEDS PROGRAMMING <br /> x1 <br />- VAV (Variable-Air-Volume) Wiring Package for Commercial Fans. <br />0-10VDC Speed Control Variable Frequency Drive Included <br /> x1 <br />- Low ambient cooling controls down to 0F ambient temperatures. To be used in recirculating <br />applications. <br /> x1 <br />- Occupied Scheduling Defaulted for IBT/RTU. x1 <br />- VERIZON CELLULAR KIT, WIRED ANTENNA AND VERIZON DATA. USED WITH FAN. x1 <br />- Single Point Electrical Connection for RTU. QNTY 1 750va Transformer Used. If a Non-DCV <br />Prewire controls this unit, the #28, #47, "MA", or "E2" Option Prewire must be selected. Do not <br />provide supply starter in prewire. <br /> x1 <br />- FARS KITCHEN MUA/RTU • Occupied/Unoccupied Scheduling • Space Temp Control • Heating <br />and Cooling Activation Based On Either Set Point • Manual Blower Mode • Smoke Detector Interlock <br />• Space Sensor Ships Loose Includes 1 Space HMIs. <br /> x1 <br />- 10 Ton Modulating Cooling Option, 208/230V. Size 1 Cabinet, R454B Refrigerant, Variable Speed <br />Inverter Duty Compressor, ECM Condensing Fan(s). <br /> x1 <br />- 10 Ton Cooling Only Modulating Reheat Option for Space Control - Size 1 Cabinet, R454B x1 <br />- RTU Size 1 No Return x1 <br />- 2" Merv 13 Filters for Size 1 RTU. <br />QTY 4, 16 x 16 x 2 Merv 13 Filters <br /> x1 <br />- 2" Merv 8 Filters for Size 1 RTU. <br />QTY 4, 16 x 16 x 2 Merv 8 Filters <br /> x1 <br />- Option for Metal Mesh Filters in RTU1 OA Intakes x1 <br />- RTU Fixed 100% Outdoor Air Intake. x1 <br />- RTU Compressor Oil Sensor Factory Installed. M12 Style Connector. x1 <br />- RTU Size 1 Side Discharge x1 <br />- R454B Refrigerant Leak Detector Option. Includes 20% LFL sensor and harness. x1 <br />- Full Bottom Curb Corner. Base flange corners fully welded or staked by factory. x1 <br />- Size 1 RTU Curb Duct Hanger - Adjustable Duct Hanger Support Brackets installed for both return <br />and discharge duct. <br /> x1 <br />- DOAS-1 Curb CRB41X71X18INS Insulated On Fan #2 Flat Curb x1 <br />NOTE: Assumed mounted on grade with side discharge. Assumed 208v.3ph input power. <br />Electrical System #1 - Job #8393124 <br />SC-311110MA 3 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in <br />Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room temperature <br />sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR <br />USE WITH VFD. Includes 1 Duct Thermostat kit. <br /> x1