Laserfiche WebLink
Friday, December 5, 2025 Quote #: 8393124 FARS - The Monarch - South Bend IN <br /> <br />Page 2 of 7 <br />- Tank-based Fire Protection System equipped with Electronic Detection utilizing CORE board as a <br />Listed Release Mechanism. Installed in Hood Utility Cabinet with integral hood prewire panel. <br /> x1 <br />- Pressure Switch - Monitors Tank Pressure, Supervised Signal, TANK FIRE SUPPRESSION x1 <br />- SC-EGVA1 GAS VALVE - 1" Electrical Shutoff Valve for use with HMI reset, 110V, 60Hz <br />(#8214250). Includes upstream strainer assembly. <br /> x1 <br />Fan #1 DU85HFA - Exhaust Fan (KEF-1) - Job #8393124 <br />DU85HFA High Speed Direct Drive Centrifugal Upblast Exhaust Fan with speed control (speed <br />control included for single phase only), disconnect switch and 15-3/4" wheel. <br />Exhaust Fan handles 1750 CFM @ -1.000" wc ESP, Fan runs at 1412 RPM. <br />Exhaust Motor: 1.000 HP, 1 Phs, 208 V, 60 Hz, 6.9 FLA, TEAO-ECM (Totally Enclosed Air Over <br />Electronically Commutated Motor) <br /> x1 <br />- Multi-Conductor - Single Shielded Twisted Pair Cable, 18 AWG stranded (19x30) TC conductors, <br />plenum, FEP insulation, overall shield (100% coverage), 20 AWG stranded TC drain wire, FEP <br />jacket. Priced per foot. For use with CORE Interlock Network, light dimming 0-10VDC reference <br />signal, and PWM signal from ECPM03 to ECM. <br /> x30 <br />- Grease Cup for kitchen-duty centrifugal exhaust fans, <br />Box Dimensions 17-1/8 L X 5-1/16 W X 3-3/4 H (20 Gauge) (Includes Down Spout) <br /> x1 <br />- DU/DR85HFA Gasketing Kit - Thermeez Woven Ceramic Tape - 1/4" x 1" with adhesive back - <br />Max Temp 1500°F. To be applied between fan base and grease duct. Installed under fan base 1/2" <br />from the inside. Installed at the plant. <br /> x1 <br />- Through Wall Curb Mount Installation Option. x1 <br />- HINGE KIT - Heavy Duty Hinge kit with locking spring pin for exhaust fan roof curbs. Includes <br />Hardware to attach hinge to curb and hinge to base. 10 GA Galvanized. <br /> <br />Note: Requires 16GA curb or 18GA curb with 16GA back plate - (9"x9" cut size). <br /> x1 <br />- Wall Mount Construction for Direct Drive Fan. Through-Bolt mount motor for extra support in wall <br />mount application. Vibration isolator mounts not used. <br /> x1 <br />- Disconnect Switch Loose - Wire Is Extended 10' To Allow Remote Mounting Of The NEMA 3R <br />Enclosure & Switch. Cord Fittings Are Installed In Switch Box. 10-32 Hardware and 7/8" Plug Are <br />Installed In Apron Switch Mounting Holes. <br /> x1 <br />- ECM Wiring Package for exhaust motors with PWM signal from ECPM03 prewire. x1 <br />- KEF-1 Curb CRB23x24E On Fan #1 Flat Curb x1 <br />- Vented Base for Curb x1 <br />Fan #2 CAS-HVAC1-I.200-15-10T-DOAS - Heater (DOAS-1) - Job #8393124 <br />CAS-HVAC1-I.200-15-10T-DOAS RTU with Indirect Fired Heat and 15" Direct Drive Plenum Fan, 1 <br />Furnace, Electronic Full Modulation, Constant 81% Efficiency, and 6:1 Max Turndown for NG, (5:1 <br />Max Turndown for LP). Stainless Steel Burner and Heat Exchanger. Supply Fan handles 1750 CFM <br />@ 1.000" wc ESP, Fan runs at 1452 RPM. Heater supplies 162000 BTUs. 77°F Temperature Rise. <br />[Fuel: Natural Gas] Input: 200000 BTUs. Supply Motor: 2.000 HP, 3 Phs, 208 V, 60 Hz, 6.1 FLA, <br />ODP, Premium (E-Plus3) Eff. Side Discharge - Air Flow Left -> Right <br /> x1 <br />- Cooling Override x1 <br />- Gas Manifold for RTU 1-1 GM - BTU 0 - 400001 - 7 in. w.c. - 14 in. w.c., No Insurance Requirement <br />(ANSI), BV250-66 <br /> x1 <br />- Clogged Filter Switch with Notification on HMI x1 <br />- Ship Loose Gas Strainer. To be installed upstream of unit connection. 3/4" Connection x1 <br />- VFD factory mounted and wired in unit control vestibule. x1 <br />- Gas Pressure Gauge, 0 to +10 Inches Wc., 2.5" Diameter, 1/8" Thread Size, Rear Thread x1 <br />- Gas Pressure Gauge, 0-35", 2.5" Diameter, 1/4" Thread Size x1 <br />- Commercial Smoke Detector Interlock (Detector By Others) x1