My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
330 West Navarre Street_AA 2026-0421
sbend
>
Public
>
Historic Preservation
>
2026
>
May
>
Administrative Approvals
>
330 West Navarre Street_AA 2026-0421
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2026 3:36:38 PM
Creation date
4/29/2026 3:34:08 PM
Metadata
Fields
Template:
South Bend HPC
HPC Street Address
330 West Navarre Street
HPC Document Type
Certification
HPC Local Historic District
ix. Chapin Park
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Revised: April-2017 PDS 09-1320 Page 1 of 4 <br />Product Data Sheet <br />MULE-HIDE STANDARD REINFORCED AND <br />FR REINFORCED EPDM MEMBRANE <br /> <br />PRODUCT DESCRIPTION <br /> <br />Mule-Hide Standard Reinforced EPDM is a high performance, <br />polyester reinforced membrane that stands up to tearing, <br />impacts, punctures and normal roof traffic. The elastomeric <br />properties of the EPDM membrane compensate for thermal <br />shock and building movement. EPDM membranes provide <br />excellent resistance to ozone and aging. The membrane is <br />manufactured in accordance with the guidelines established by <br />the RMA (Rubber Manufacturers Association) and meets or <br />exceeds the ASTM Standard Specification D 4637, Type II. Also <br />available as a Fire retardant (FR) membrane that is specially <br />formulated to inhibit spread of flame and meet or exceed code <br />body testing criteria for fire retardant roofing membranes. <br /> <br />Mule-Hide STANDARD REINFORCED and FR REINFORCED EPDM membranes are available with in-seam <br />tape that is pre-applied to the sheet. See below for sizes available. <br /> <br />BASIC USES <br /> <br />The Standard Reinforced and FR Reinforced EPDM membrane is used in mechanically attached and fully <br />adhered roofing systems in new construction, reroofing and recover (retrofit) applications. It may also be used as <br />flexible membrane flashings for walls, curbs, etc, when installing an EPDM membrane roofing systems. The <br />system must be installed over acceptable roof insulation or other suitable substrate. See the Mule-Hide EPDM <br />Specifications Manual for complete specifications and details. <br /> <br />SPECIFICATIONS <br /> <br />Physical Properties* Test Method SPEC. (Pass) Typical Standard <br />Tolerance on Nominal Thickness, % ASTM D 751 + 10 + 10 <br />Thickness Over Scrim, min, in.(mm) <br /> .045 <br /> .060 <br /> .075 <br />ASTM D 4637 <br />Annex <br /> <br />0.015 (0.381) <br /> <br /> <br />0.016 (0.406) <br />0.020 (0.508) <br />0.032 (0.810) <br />Weight, lbm/ft2 (kg/m2) <br /> .045 <br /> .060 <br /> .075 <br /> <br /> <br />0.27 (1.3) <br />0.39 (1.9) <br />0.48 (2.3) <br />Elongation, Ultimate, min, % <br /> .045 & .060 <br /> .075 <br />ASTM D 412 <br />Die C <br /> <br />250** <br /> <br />480*** <br />500*** <br />Tear Strength min, lbf (N) <br /> .045, .060 & .075 <br />ASTM D 751 <br />B Tongue Tear <br /> <br />10 (45) <br /> <br />70 (311) <br />Breaking Strength, min, lbf(N) <br /> .045, .060 <br /> .075 <br />ASTM D 751 <br />(Grab Method) 90(400) <br /> <br />140(623) <br />177 (787) <br />Factory Seam Strength, min. ASTM D 816 <br />(Modified) <br />Membrane <br />Rupture <br />Membrane <br />Rupture <br />Brittleness point, max, deg.F (deg.C)* ASTM D 2137 -49(-45) -49(-45) <br />Resistance to Heat Aging* <br /> Properties after 4 weeks @ 240oF(116oC) <br /> Breaking Strength, min, lbf(N) <br /> Elongation, Ultimate, min, % <br /> Linear Dimensional Change, max, % <br />ASTM D 573 <br /> <br />ASTM D 751 <br />ASTM D 412 Die C <br />ASTM D 1204 <br /> <br /> <br />80(355) <br />200** <br />+ 1.0 <br /> <br /> <br />182 (823) <br />250** <br />-1.0
The URL can be used to link to this page
Your browser does not support the video tag.