My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
26-14 Resolution to Grant the Issuance of Conditional Scrap Metal / Junk Dealers / Recycling Operations Licenses
sbend
>
Public
>
Common Council
>
Legislation
>
Upcoming Bills
>
2026
>
05-11-2026
>
26-14 Resolution to Grant the Issuance of Conditional Scrap Metal / Junk Dealers / Recycling Operations Licenses
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2026 2:27:03 PM
Creation date
4/22/2026 2:26:50 PM
Metadata
Fields
Template:
City Council - City Clerk
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Pass 605.4.2-Power supply <br /> Relocatable power taps shall be directly connected to a <br /> permanently installed receptacle. <br /> Pass 605.5-Extension cords <br /> (`-/) Extension cords and flexible cords shall not be a substitute <br /> for permanent wiring.Extension cords and flexible cords <br /> shall not be affixed to structures.extended through walls. <br /> ceilings or floors.or under doors or floor coverings,nor shall <br /> such cords be subject to environmental damage or physical <br /> impact.Extension cords shall be used only with portable <br /> appliances. <br /> Pass 605.5.1*-Extension cords <br /> Extension cords shall be plugged directly into an approved <br /> receptacle.except for approved multiplug extension cords, <br /> shall serve only one portable appliance. <br /> Pass 605.6•Unapproved conditions <br /> (. ) Open junction boxes and open-wiring splices shall be <br /> prohibited.Approved covers shall be provided for all switch <br /> and electrical outlet boxes. <br /> Pass 703.1-Maintaining <br /> The required fire-resistance rating of fire-resistance-rated <br /> construction(including walls,firestops.shaft enclosures. <br /> partitions.smoke barriers,floors.fire-resistive coatings and <br /> sprayed fire-resistant materials applied to structural members <br /> and fire-resistant joint systems)shall be maintained.Such <br /> elements shall be visually inspected by the owner annually <br /> and properly repaired,restored or replaced when damaged, <br /> altered.breached or penetrated.Where concealed.such <br /> elements shall not be required to be visually inspected by the <br /> owner unless the concealed space is accessible by the <br /> removal or movement of a panel.access door,ceiling tile or <br /> similar movable entry to the space.Openings made therein <br /> for the passage of pipes.electrical conduit.wires.ducts.air <br /> transfer openings and holes made for any reason shall be <br /> protected with approved methods capable of resisting the <br /> passage of smoke and fire.Openings through fire-resistance- <br /> rated assemblies shall be protected by selfor automatic- <br /> closing doors of approved construction meeting the fire <br /> protection requirements for the assembly <br /> Pass 703.2'-Opening Protectives <br /> Opening protectives shall be maintained in accordance with <br /> the rules of the commission.Where allowed by the fire code <br /> official,the application of field-applied labels associated with <br /> the maintenance of opening protectives shall follow the <br /> requirements of the approved third-party certification <br /> organization accredited for listing the opening protective.Fire <br /> doors and smoke barrier doors shall not be blocked or <br /> obstructed.or otherwise made inoperable.Fusible links shall <br /> be replaced promptly whenever fused or damaged.Fire door <br /> assemblies shall not be modified_ <br /> Pass 901.5.1-Occupancy <br /> (7%) It shall be unlawful to occupy any portion of a building or <br /> structure until the required fire detection.alarm and <br /> suppression systems have been tested and approved. <br /> GENERATED ON 3/17/26, 10:39 AM 8 OF 10 <br />