Laserfiche WebLink
Pass 24.6-General signage <br /> (;) The installing contractor shall provide a general information <br /> sign used to determine system design basis and information <br /> relevant to the inspection,testing,and maintenance <br /> requirements required by NFPA 25.Standard for the <br /> Inspection.Testing.and Maintenance of Water-Based Fire <br /> Protection Systems 24.6.1.1 Such general information shall <br /> be provided with a permanently marked weatherproof metal <br /> or rigid plastic sign.secured with corrosion-resistant wire. <br /> chain,or other acceptable means.24.6.1.2 Such signs shall <br /> be placed at each system control riser.antifreeze loop.and <br /> auxiliary system control valve.24.6.2 The sign shall include <br /> the following information:(1)Name and location of the facility <br /> protected(2)Occupancy classification(3)Commodity <br /> classification(4)Presence of high-piled and/or rack storage <br /> (5)Maximum height of storage planned(6)Aisle width <br /> planned(7)Encapsulation of pallet loads(8)Presence of solid <br /> shelving(9)Flow test data(10)Presence of <br /> flammable/combustible liquids(11)Presence of hazardous <br /> materials(12)Presence of other special storage(13)Location <br /> of auxiliary drains and low point drains on dry pipe and <br /> preaction systems(14)Original results of main drain flow test <br /> (15)Name of installing contractor or designer(16)Indication <br /> of presence and location of antifreeze or other auxiliary <br /> systems <br /> Pass 304.1-Waste accumulation prohibited <br /> Combustible waste material creating a fire hazard shall not be <br /> allowed to accumulate in buildings or structures or upon <br /> premises. <br /> Pass 304.1.1-Waste material <br /> (✓) Accumulations of wastepaper.wood,hay,straw,weeds.litter <br /> or combustible or flammable waste or rubbish of any type <br /> shall not be permitted to remain on a roof or in any court, <br /> yard,vacant lot,alley.parking lot.open space,or beneath a <br /> grandstand.bleacher.pier.wharf or other similar structure. <br /> Pass 304.1.2'-Vegetation <br /> (i) Weeds.grass.vines or other growth that is capable of being <br /> ignited and endangering property.shall be cut down and <br /> removed by the owner or occupant of the premises. <br /> Pass 315.1-General <br /> l,!i Storage shall be in accordance with Sections 315.2 through <br /> 315.4. <br /> Pass 315.3.1-Ceiling clearance <br /> Storage shall be maintained 2 feet(610 mm)or more below <br /> the ceiling in nonsprinklered areas of buildings or a minimum <br /> of 18 inches(457 mm)below sprinkler head deflectors in <br /> sprinklered areas of buildings.Exception:Sidewall storage to <br /> a maximum depth of thirty(30)inches(seventy-six and two- <br /> tenths(76.2)centimeters)shall be acceptable to the ceiling in <br /> non-sprinklered buildings. <br /> Pass 315.3.2-Means of egress <br /> 0 Combustible materials shall not be stored in exits or <br /> enclosures for stairways and ramps. <br /> Pass 315.3.3-Equipment rooms <br /> 0 Combustible material shall not be stored in boiler rooms, <br /> mechanical rooms or electrical equipment rooms. <br /> GENERATED ON 3/17/26, 10:39 AM 5 OF 10 <br />