My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2025
>
Opening of Quotations/Proposals/Qualifications
>
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 4:25:16 PM
Creation date
2/11/2025 1:57:02 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
2/11/2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
3S5 I F� <br />C us <br />Classified by <br />Underwriters Laboratories, Inc. <br />to UL 1479 and CAN1ULC-S115 <br />System No. W-L-1465 <br />ANSI/UL1479 (ASTM E814) <br />F Rating —1 or 2 Hr (See Item 1) <br />T Rating — 0 and 114 Hr (See Item 1) <br />L Rating At Ambient — Less Than 1 CFM/Sq Ft <br />L Rating At 400 F — Less Than 1 CFM/Sq Ft <br />CAN/ULC S115 <br />F Ratings —1 or 2 Hr (See Item 1) <br />FT Rating — 0 and 1/4 Hr (See Item 1) <br />FH Rating —1 or 2 Hr (See Item 1) <br />FTH Rating —0 and 1/4 Hr (See Item 1) <br />L Rating At Ambient — Less Than 1 CFM/Sq Ft <br />L Rating At 400 F — Less Than 1 CFM/Sq Ft <br />SECTION A -A <br />co <br />Wall Assembly — The 1 or 2 hr fire rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified <br />in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the <br />following construction features: <br />A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) <br />lumber spaced max 16 in. (406 mm) OC. Steel studs to be min 3-1/2 in. (89 mm) wide and spaced max 24 in. (610 mm) OC. <br />B. Gypsum Board* — Thickness, type, number of layers and orientation shall be as specified in the individual Wall and Partition Design. Max <br />diam of opening is 10 in. (254 mm). <br />The hourly F, FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. The T, FT, FTH <br />Ratings are 0 and 1/4 hr for 1 and 2 hr rated wall assemblies, respectively. <br />2. Steel Sleeve — Cylindrical sleeve fabricated from min 0.016 in. (0.41 mm) thick galv sheet steel and having a min 1 in. (25 mm) lap along the <br />longitudinal seam. Sleeve installed by coiling the sheet steel to a diam smaller than the through opening, inserting the coil through the <br />openings and releasing the coil to let it uncoil against the circular cutouts in the gypsum board layers. The ends of the steel sleeve shall be <br />flush with or extend max 1 in. (25 mm) beyond each surface of the wall. <br />Reproduced by HILTI, Inc. Courtesy of <br />Underwriters Laboratories, Inc. <br />Hilti Firestop Systems January 26, 2015 page:1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.