My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2025
>
Opening of Quotations/Proposals/Qualifications
>
Opening of Quotations - WWTP Server Room Fire Suppression System Proj No 124-038R - Larson-Danielson
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 4:25:16 PM
Creation date
2/11/2025 1:57:02 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
2/11/2025
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Sensor Features <br />The sensors through the fire alarm control panel provide a real time status as to the condition of the <br />system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all <br />programmable options. The system also allows for a day/night mode where the panel automatically <br />adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke <br />detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the <br />point that it can no longer maintain the programmed sensitivity. <br />Micro Input Module provides a small foot print contact module for mounting inside an enclo- <br />sure. <br />Single Action Addressable Pull Station. <br />Dual Action Addressable Pull Station. <br />Single Input Module is a standard contact module with an LED that mounts into a 4" square <br />electrical box. <br />Dual Input Module is a device that can monitor two distinct inputs with a single device or in <br />a Class A mode. <br />Two Relay Two Input module provides two form C relays that are individually controlled by <br />the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also <br />provides two contact inputs. <br />Notification Appliance Circuit module is an addressable remote appliance circuit controlled <br />by the panel. <br />Zone Module is used to connect conventional 2-wire smoke detectors to the system. <br />Isolater Module interrupts a short on the SLC and prevents the short from affecting protected <br />devices on the loop. <br />Relay Module that provides one form C relay controlled by the control panel. Relay is rated <br />for 2 amps at 30VDC or 0.5 amps at 125VAC. <br />Module provides a single addressable LED that is controlled by the control panel. <br />Speaker Module provides switching for two audio channels. <br />Addressable LED and key switch that mounts in a single gang box. <br />DUCTR Remote Test Switch that mounts in a single gang box. <br />One Relay One Input Module provides one form C relay and one input. The relay is rated at <br />2 amps at 30VDC or 0.5 amps at 125VAC. <br />Dimensions <br />roR - . : 0 T.EPTH = 3.75 " <br />0 0 <br />DOOR= 16.07" <br />g4ClBOX= 15.77" DEPTH = 3.84" <br />s❑ <br />LEFT SIDE <br />BOTTOM <br />0 <br />C) <br />RIGHT SIDE <br />DS1317 Revised: 23-Jul-2020 <br />Page 4 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.