Laserfiche WebLink
1/4" (I <br />FN <br />L <br />18648 <br />18649 <br />18650 <br />18651 <br />nm) <br />r <br />Pilot Actuation End Line Tee (P/N 18611) <br />A 1/4 in (8 mm) FNPT by MNPT brass branch tee mounts <br />to the final pneumatic valve actuator to facilitate attach- <br />ment of the vent check to the pilot actuation line. <br />Flex Hose (P/N See Chart) <br />Flex hoses are 3/16 in (7 mm) Teflon® lined stainless <br />steel wire braided hoses of varying lengths with 1/4 in (8 <br />mm) 37o female JIC flare fittings. They are utilized to in- <br />terconnect cylinders when a multi -cylinder arrangement <br />is required. A 1/4 in (8 mm) 37o male JIC flare x male JIC <br />flare adapter (P/N 18777) is available to connect lengths <br />of flex hose together. <br />16 in (406 mm) <br />24 in (610 mm) <br />34 in (864 mm) <br />40 in (1016 mm) <br />SUPPLEMENTAL COMPONENTS <br />Supplemental components complete various system arrangements. <br />5 �2" <br />(133 mm) <br />DS1258 Revised: 21-Dec-2023 <br />r <br />1/4" (8 mm) <br />FNPT Pipe <br />Connection <br />k <br />1 1/4" (32 mm) <br />FNPT <br />Discharge Pressure Switch (P/N 97428) <br />The discharge pressure switch is used in the system to <br />provide positive indication of agent discharge and to initi- <br />ate the shut down of equipment that may deplete agent <br />concentration. The pressure switch is a single pole, dou- <br />ble throw (SPDT) switch with contacts rated 15 Amps at <br />(20 mm) 125/250/480 VAC and 0.5 Amps at 125 VDC. It has a <br />IT Conduit NEMA 4X and IP66 enclosure. <br />inn—tinn <br />Manifold Check Valve (P/N 18547) <br />In a multiple cylinder arrangement where the secondary <br />and primary cylinders share a common manifold or in a <br />main / reserve arrangement, a 1 1/4 in (32 mm) FNPT <br />manifold check valve must be placed between the dis- <br />charge outlet of each cylinder and the discharge mani- <br />fold to prevent back flow from the manifold should the <br />system be inadvertently discharged when one or more <br />cylinders are disconnected for maintenance. The take- <br />out for the valve is 1.375 in (35 mm). <br />Page 7 of 10 <br />