<br />40 <br /> <br /> <br /> <br /> <br />4. Reporting. VEREGY will provide CUSTOMER with a Guaranteed Savings Reconciliation Report(s) according to the <br />schedule below. CUSTOMER will assist VEREGY in generating the savings reconciliation report by providing VEREGY with <br />all information requested as identified in Section 3.2 of Attachment D. Data and calculations utilized by VEREGY in the <br />preparation of its Guaranteed Savings Reconciliation Report will be made available to CUSTOMER along with such <br />explanations and clarifications as CUSTOMER may reasonably request. <br /> <br />Guaranteed Savings Reconciliation Report Schedule <br /> <br /> Report Delivered Savings Represented <br />Report 1 90 days following end of <br />Guarantee Year <br />Year 1 Savings <br />Subsequent Reporting <br />Years <br />90 days following end of <br />Guarantee Year <br />Subsequent Year Savings <br /> <br />The fees associated with the Guaranteed Savings Reconciliation Report are given in Attachment C. <br /> <br /> <br />5. Savings Measurement & Verification Plan <br />VEREGY will verify the savings using the methodologies given in the table below. Calculation” means the savings have been <br />calculated and agreed to by CUSTOMER and VEREGY. “Measurement” requires measurements to determine the actual <br />retrofit performance. In the “Measurement” cases, the measured parameters, time of measurement and quantity of equipment to <br />be measured are identified. The actual operation of the Facility is the responsibility of CUSTOMER. This includes properly <br />maintaining the equipment, the future hours of operation based on a change in mission, or capacity and variations in weather or <br />unit energy costs. <br /> <br />After review of the measurement and verification protocol options, CUSTOMER and VEREGY have agreed that <br />measurements noted in this attachment meet CUSTOMER’S needs for verification of Energy Savings. <br /> <br />Measurement and Verification Methodology for Energy Conservation Measures <br /> <br />Facility <br />ECM <br /># ECM Description <br />IPMVP <br />Option <br />Measurement and Verification Procedures <br />Method Measured <br />Parameter <br />Measurement <br />Interval <br />Dewatering 1 Solar B Measurement kWh Production Annually <br />HVAC <br />Building <br />Controls <br />2 Building Automation <br />System <br /> Stipulated Verification that <br />existing <br />compressor has <br />been removed <br />One Time <br />Administration <br />Building <br />3 LED Retrofit B Measurement Light fixtures <br />measured <br />One Time <br />Headworks 4 ACCU Replacement Stipulated Verification of <br />new efficiency <br />rating <br />One Time <br />Dewatering 5 Office AC Unit Stipulated Verification of <br />new efficiency <br />rating <br />One Time <br /> <br /> <br />The following describes the Measurement and Verification procedures, formulas, and estimated values which may be used in <br />the calculation of the Energy Savings. % of calculated savings that are guaranteed are given in the Energy Conservation <br />Measures Savings Guarantee Table. <br /> <br />ECM #1. Solar Savings: