Laserfiche WebLink
4.1.3. Single or Multiple Communication Gateways <br />Multiple communication gateways should be installed if the answer to at least one of these <br />questions is Yes: <br />• Are there more than 20 charging stations? <br />• Are the charging stations installed on more than one floor? <br />• Are the charging station signals to the communication gateway and/or to each other <br />blocked by any structure or obstruction (i.e., no line of sight between charging <br />stations and/or between charging stations and the communication gateway)? <br />• Are the charging stations more than 48.7 m (160 feet) apart and/or more than 48.7 m <br />(160 ft) away from the communication gateway? <br />_0 .0 _0 .0 _0 .0 .0 <br />Gateway 1 <br />Charging Station(s) 1 2 3 4 5 ... 20 <br />Gateway 2 <br />Charging Station(s) 1 2 3 4 5 ... 20 <br />NOTE: Each gateway only has one LAN port; therefore, multiple gateways cannot be daisy <br />chained. In the case of Ethernet/LAN hardwire connection, an Ethernet switch (customer <br />supplied) rated for the operating environment and with adequate number of LAN ports is <br />required. <br />13 <br />