Laserfiche WebLink
Conduit Positioning <br />mz.,a <br />[63.59cm] <br />[6985cm] <br />[6350cm] <br />O <br />a <br />[�so, <br />With 2 conduits and a cascading kit: <br />• The pedestal base opening has been sized to accept 2 PVC conduits <br />up to 2 inches in diameter each, side by side. <br />• The 2 conduits must be placed side by side and centered between <br />the anchor pins which are located on each side of the pedestal's <br />access door. <br />• On the other axis, the conduits should be off center, toward the door, <br />with the conduits' outer envelope maintained at a minimum distance <br />of 1.25 inch (32 mm) from the axis passing through the center of <br />the pins. <br />Cascading single station pedestals: <br />• When a single charging station head is mounted on a pedestal, it <br />should always be facing the parking space it is serving. <br />• To have the head facing the parking space, the access door of the <br />pedestal must be facing left or right. <br />• To have the access door facing left or right, the conduits must be <br />placed side by side, as shown. <br />Cascading dual station pedestals: <br />• When 2 charging station heads are mounted on a pedestal, they <br />should always be facing left and right. <br />• To have the heads facing left and right, the pedestal's access door <br />should be facing the rear of the pedestal. <br />• To have the access door facing the rear of the pedestal, the conduits <br />must be placed side by side, as shown. <br />CoRe+T" 122 <br />Cable management system and pedestal installation guide <br />