Laserfiche WebLink
Ludowici Interlocking Tile Installation Manual <br />33www.ludowici.com <br />Figure 33.2 Flashing at Low Slope to High Slope TransitionFigure 33.1 Flashing at High Slope to Low Slope Transition <br />Field Tile <br />Cant Strip <br />16 oz. Copper Flashing <br />6" Minimum Upslope and <br />4" Minimum Downslope <br />Sealant <br />Underlayment <br />Field Tile <br />Cant Strip <br />16 oz. Copper Flashing <br />6" Minimum Upslope and <br />4" Minimum Downslope <br />Sealant <br />Underlayment <br />Under Eave <br />Extended 16 oz. <br />Copper Drip Edge <br />16 oz. Copper Flashing <br />4" Minimum Downslope <br />Sealant <br />Field Tile <br />Ice and Water <br />Shield <br />16 oz. Copper Drip Edge <br />Under Eave <br />Figure 33.3 Built in Gutter Detail for Flat Interlocking Tile Figure 33.4 Built in Gutter Detail for French Interlocking Tile <br />Extended 16 oz. <br />Copper Drip Edge <br />16 oz. Copper Flashing <br />4" Minimum Downslope <br />Sealant <br />French <br />Field Tile <br />Ice and Water <br />Shield <br />Cant Strip <br />14" <br />Flashing at Pitch Change and Built In Gutter