My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Opening of Bids - SB City Hall Renovations Proj No. 124-001 -Michuda-Cruz JV
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2024
>
Opening of Bids
>
Opening of Bids - SB City Hall Renovations Proj No. 124-001 -Michuda-Cruz JV
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/17/2025 1:58:53 PM
Creation date
10/24/2024 12:42:52 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Projects
Document Date
10/22/2024
Callout
ID:
1
Creator:
Created:
10/24/2024 12:43 PM
Modified:
10/24/2024 12:43 PM
Text:
Remove curtain on higher floors for delivery
Text box
ID:
1
Creator:
Created:
10/24/2024 12:43 PM
Modified:
10/24/2024 12:43 PM
Text:
ELEVATORS
ID:
2
Creator:
Created:
10/24/2024 12:43 PM
Modified:
10/24/2024 12:43 PM
Text:
Dumpsters
ID:
3
Creator:
Created:
10/24/2024 12:43 PM
Modified:
10/24/2024 12:43 PM
Text:
Field Office
Line
ID:
1
Creator:
Created:
10/24/2024 12:43 PM
Modified:
10/24/2024 12:43 PM
Rectangle
ID:
1
Creator:
Created:
10/24/2024 12:43 PM
Modified:
10/24/2024 12:43 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CODE LEGENDEXITSEMI RECESSED FIRE EXTINGUISHER CABINET W/ FIRE EXTINGUISHER. VERIFY LOCATIONS AND QUANTITIES W/ APPLICABLE CODES, OWNER AND FIRE MARSHAL.FEC2 HR RATED FIRE BARRIER (ESTIMATED - EXISTING TO REMAIN)NOTES:A. FIRE EXTINGUISHER LOCATIONS SHOWN ARE SUGGESTED LOCATIONS ONLY. LOCATIONS OF FIRE EXTINGUISHERS AND CABINETS SHALL COMPLY WITH NFPA 10. CONTRACTOR TO VERIFY QUANTITY AND EXACT LOCATIONS WITH AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION.B. RATED WALLS SHALL BE PERMANENTLY AND APPROPRIATELY IDENTIFIED IN ACCORDANCE WITH THE REQUIREMENTS SET FORTH IN THE BUILDING CODE. REF TO STENCILING DIAGRAM ON LIFE SAFETY DRAWINGS.C. LIFE SAFETY DRAWINGS SHOULD BE VIEWED AT FULL SCALE AND IN COLOR.<###FT>MAXIMUM TRAVEL DISTANCE PER FLOOR(# / #)CALCULATED EGRESS LOAD OVER EGRESS CAPACITY(#)CALCULATED OCCUPANT LOAD OF AREA282 SFEX. MECH.311 SFEX. MECH.126 SFEX. STAIR417 SFEX. MEP192 SFEX. MEP26 SFEX. HK125 SFEX. STAIR239 SFEX. CORR.132 SFSMALLCONFERENCE107 SFOFFICE236 SFOFFICERedundant RoomOFFICENot EnclosedOFFICE112 SFOFFICE284 SFINTAKE155 SFMEN'S RR108 SFPUBLICCONFERENCEROOM108 SFOFFICE605 SFOPENOFFICE716 SFHALL86 SFEX. STOR.323 SFBLDG.PERMITS140 SFWOMEN'SRR1,411 SFLOBBY524 SFEX. CORR.59 SFRR59 SFRR123 SFSTORAGE99 SFBREAK245 SFOPENOFFICE44 SFPRINT187 SFONE STOPSHOP104 SFRECEPTION79 SFSECURITY124 SFSMALLCONFERENCE(1)(1)(1)(1)(2)(2)(2)(2)(2)(2)(2)(1)(3)(1)(9)(4)(2)(2)(2)(8)(1)(9)(27/480)(29)(7)(24/240)(24/240)(179/280)MAX.<293FT> MAX.<296FT>MAX.<88FT><128FT>(51/480)FECFECLETTERING TO BE 3" MIN IN HEIGHT WITH A MIN 3/8" STROKE IN A CONTRASTING COLOR INCORPORATING THE SUGGESTED WORDING: "FIRE WALL or FIRE BARRIER--PROTECT ALL OPENINGS". (REF TO LIFE SAFETY DRAWINGS FOR RATED WALL LOCATIONS AND TYPES)CEILING3" MINACCESSIBLE CONCEALED FLOOR, FLOOR-CEILING OR ATTIC SPACENOTES:A. MARK ALL FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS. B. LOCATE WITHIN 15'-0" OF THE END OF EACH WALL AT INTERVALS NOT EXCEEDING 30' MEASURED HORIZONTALLY198 SFEX.WOMENS126 SFEX. STAIR318 SFEX. MEP252 SFEX. MENS25 SFEX. HK127 SFEX. STAIR134 SFOFFICE140 SFOFFICE428 SFLARGECONFERENCE252 SFBREAK131 SFOFFICE151 SFOFFICEDIRECTOR127 SFDEPUTYDIRECTOR109 SFOFFICE280 SFMEDIUMCONFERENCE227 SFRECEPTION73 SFMOTHER'SROOM80 SFSTORAGE104 SFSMALLCONFERENCE232 SFSTORAGE127 SFOFFICE298 SFFINANCEDEPARTMENT82 SFPRINTER115 SFOFFICE39 SFSTORAGE153 SFCITYCONTROLLER103 SFOFFICE109 SFDEPUTYOFFICE97 SFOFFICE183 SFOFFICE162 SFSTORAGE105 SFMECH142 SFSTOR.391 SFOPENOFFICE215 SFOPENOFFICE617 SFOPENOFFICE42 SFCUBICLE176 SFOPENOFFICE493 SFCORRIDOR141 SFCENTRALMAIL108 SFHOTELINGAREA(2)(1)(1)(1)(1)(1)(1)(1)(1)(1)(1)(1)(2)(2)(2)(2)(2)(2)(2)(2)(2)(2)(3)(3)(2)(4)(2)(19)(2)(3)(7)(2)(7)(28)(54/180)(54/180)(58/180)(58/180)<293FT><168FT><190FT>FECFECProject NumberCERTIFIED BYISSUANCE INDEXDATE:PROJECT PHASE:9/6/2024 6:17:46 PMG101FIRST & SECONDFLOOR LIFE SAFETYPLANS2022.0034309/06/2024BID DOCUMENTSSOUTH BEND CITY HALLRENOVATION215 DR. M.L.K. JR BLVD.SOUTH BEND, IN 46601N1/8" = 1'-0"G1011FIRST FLOOR LIFE SAFETY PLANRATED WALL STENCILINGN1/8" = 1'-0"G1012SECOND FLOOR LIFE SAFETY PLANREVISION SCHEDULENO. DESCRIPTION DATE