Heavy Duty <br />Casting <br />(Refer to Std. <br />4-6) <br />Eccen tric <br />Cone <br />0 <br />4'-0" Dia. or <br />5'-0" Dia. <br />(See Note 4) <br />C.i <br />oI <br />Conc. Bench <br />(Class A) <br />�- -- <br />6" Min• <br />(T)P.)) <br />Pre-Cast <br />Conc. Bench <br />Conc. Bench Precast Manhole (Class A)(Typ.) <br />(Class A)(Typ.) ction B-Borrow Backfill Unless <br />B-Borrow Backfill Unless 4Pi <br />Flow Channel Otherwise Approved by 4% Slope <br />Otherwise Approved by (See Note 3) City Engineer �� (TY0 <br />City Engineer <br />r Grade ° <br />Adjusting Rings to Bring <br />Frame to Grade. (Refer to PLAN VIEW <br />Std. 4-6) <br />Copolymer polypropylene <br />plastic manhole steps with <br />grade 60 reinforcing <br />steel <br />Seal all Joints w/ Conseal <br />CS-102, Bidco C-56 or <br />Approved Equal. Wrap all <br />Joints with Conseal <br />CS-212 Exterior Joint Wrap <br />or Approved Equal. Apply <br />Joint Wrap Primer per <br />Manufacturer's <br />Requirements. <br />Reinforced Conc. Pre -Cast <br />Manhole <br />Flow Channel <br />-� Pipe Sizes 8" to 24" <br />4" Min. Clearance <br />- - - Between Lowest Pipe <br />Invert and Manhole - <br />Bottom Outlet Pipe <br />Flow <br />Min. Distance Between <br />Openings shall be 6" for <br />pipe up to 10" nominal <br />dia. For Larger pipes the <br />min. distance between <br />openings shall be O.D. <br />of smallest pipe <br />o ,d <br />v <br />Inlet Pipe <br />Flow <br />Base (Compacted) `O :X <br />SECTION VIEW DETAIL A <br />NOTES: <br />1. All manholes shall be manufactured and installed in compliance with ASTM C-478. <br />2. All pipe connections shall be made with integral resilient fittings complying with ASTM C-923. <br />3. Flow channel shall conform to the shape of the connecting sanitary sewer and be made through the bottom surface of the <br />manhole. The channel walls shall be formed or shaped to the full height of the crown of the outlet sewer. <br />4. Refer to manhole size vs. pipe size chart on Standard 4-2. <br />5. Completed manholes shall be tested with negative pressure (vacuum) in accordance with ASTM C-1244-93. <br />6. At manholes where a smaller diameter sewer joins a larger diameter sewer, the invert of the larger sewer shall be lowered such <br />that the elevation at 8011. of the pipe diameter of both sewers is matched (Refer to Detail A above). <br />7. The Design Engineer is to be responsible for setting pipe invert elevations to account for minor losses through the manhole. <br />TYPE A MANHOLE - STANDARD PRE -CAST <br />SCALE. 3/8" = 1'-0" <br />90, <br />The Lower 90' Arc of the Barrel of <br />the Pipe Should be in Firm Contact <br />With Undisturbed Earth. The <br />Bedding Shall be Continuous and <br />Uniform for the Length of the Pipe. <br />Small Excavations Should be Made <br />for the Bells. No Weight Shall be <br />Supported by the Bells.These <br />Should be no Larger Than <br />Necessary to Clear the Bell. <br />11. These trench and bedding details are for pipe structural requirements only. The <br />contractor is solely responsible for safety of operations. The contractor shall slope <br />trench walls, provide protective work boxes, and/or shore and brace all <br />excavations as the contractor determines necessary for safety of operations, and <br />in conformance to IOSHA Regulation 29 C.F.R. 1926, Subpart P for Trench Safety <br />Systems. <br />2. All PVC pipe for sanitary sewers shall be installed in accordance with ASTM D2321. <br />3. There shall be no rocks or stones greater than 2" in any dimension within 6" of <br />the pipe wall or bell. <br />4. Flexible Pipe: Embedment materials for bedding, haunching and initial backfill shall <br />comply with the requirements of ASTM D2321, Classes I (INDOT #8 or #9), 11 <br />(INDOT #53, #73, or B-Borrow), or III and shall be compacted as noted. Refer to <br />pipe manufacturers recommended bedding and embedment material class type <br />requirements. Removable flowable backfill shall be placed for all areas within 5 feet <br />of pavements to 12" above pipe crown. Above this limit structure backfill shall be <br />used. <br />5. Rigid Pipe: Embedment materials for bedding, haunching and initial backfill shall <br />comply with the requirements of ASTM C12 (VCP) Classes A, B, C or crushed <br />stone (INDOT #8, #9 or B-Borrow) and shall be compacted as noted. Removable <br />flowable backfill shall be placed for all areas within 5 feet of pavements to 12" <br />above pipe crown. Above this limit structure backfill shall be used. <br />6. Final backfill shall not contain debris, organic material, frozen material, unstable <br />material or boulders or stones greater than 2" in any dimension. Flowable fill <br />optional. <br />7. The placement and compaction of backfill shall not cause displacement of the <br />pipe. <br />8. For multiple pipes in some trench: <br />a. Place bedding to Spring Line of first pipe across entire trench width. <br />b. Placement of next pipe, re -excavate trench as needed. Then place bedding <br />as noted above. <br />c. For additional pipes repeat as required. <br />9. Refer to INDOT Standard Specification Section 213 for flowable fill (removable) <br />requirements. <br />Pipe Embedment - <br />(See Notes 4 and 5) <br />FLEXIBLE PIPE. <br />4 Min. Pipe Bedding <br />RIGID PIPE. <br />Pipe Shall be Bedded Firmly on <br />Undisturbed Ground. Excovote-1 <br />for Bells. No Weight Shall be <br />Supported by the Bells. <br />PIPE BEDDING DETAIL <br />(NOT TO SCALE) <br />_ Precast Manhole <br />Section <br />Flow Channel <br />:(See Note 3) Flowable Fill <br />(See Note 8) <br />Drop <br />Connection <br />Heavy Duty <br />Casting <br />(Refer to Std. <br />4-6) <br />Eccentric Cone <br />Copolymer polypropylene <br />plastic manhole steps with <br />" grade 60 reinforcing <br />steel <br />Manhole <br />Flow Channel <br />Outlet( <br />6" MJny <br />(TYP•) 1 <br />Pre -Cost - <br />Base <br />Grade Adjusting Rings to Bring <br />Frame to Grade. (Refer to <br />Std. 4-6) <br />Seal all Joints w/ Conseal <br />CS-102, Bidco C-56 or <br />Approved Equal. Wrap all <br />Joints with Conseal <br />CS-212 Exterior Joint Wrap <br />or Approved Equal. Apply <br />Joint Wrap Primer per <br />Manufacturer's <br />4'-0" Dia. or Requirements. <br />Inlet <br />Brick Dam `II Drop Connection <br />dia. of pipe " <br />8 Min. Pipe size <br />6" Min. <br />io (TYP•) <br />Conc. Bench Flowable Fill (Removable) <br />(See Note 7) <br />(Class A) <br />4" Min. Clearance <br />_� Between Lowest Pipe <br />Invert and Manhole <br />Bottom <br />SECTION VIEW B-Borrow <br />(Compacted) <br />NOTES: <br />1. All manholes shall be manufactured and installed in compliance with ASTM C-478. <br />2. All pipe connections shall be made with integral resilient fittings complying with ASTM C-923. <br />3. Flow channel shall conform to the shape of the connecting sanitary sewer and be made through the bottom surface of the <br />manhole. The channel walls shall be formed or shaped to the full height of the crown of the outlet sewer. <br />P 9 <br />4. Refer to manhole size vs. pipe size chart. <br />5. Completed manholes shall be tested with negative air pressure vacuum in accordance with ASTM C-1244-93. <br />P 9 P (vacuum) <br />6. Refer to INDOT Standard Specification Section 213 for removable flowable fill requirements. <br />Z The Design Engineer is to be responsible for setting pipe invert elevations to account for minor losses through the manhole. <br />STANDARD DROP MANHOLE <br />SCALE. 1/4" = 1'-0" <br />Finished Grade <br />Backfill in Streets. Allevs or <br />Driving Areas: Backfill Shall be of <br />Select Native Granular Material or <br />B-Borrow Material Free of Debris, <br />Organic Material and Large Stones. <br />Placed in 6" Layers, Solidly <br />Tamped to Sub -Grade of Street <br />Base. Backfill Shall be Compacted <br />to 100% Standard Proctor Density. <br />Backfill in Easement or Open <br />Areas: Backfill Material Shall Compaction not Req'd. <br />be of Select Native Granular if Using Flowable Fill <br />Material, Placed in 12" Layers, <br />Free of Debris, Organic (INDOT Spec.) <br />Material, and Large Stones. <br />Backfill Shall be Compacted to <br />951'. Standard Proctor Density. <br />Min. Width "W" Geotextile Required if <br />=1.25 x O.D. + 12" 1-#8 or #9 Aggregate is <br />Mechanically Tamped in 6" Layers, <br />Compact to 95% Standard Proctor <br />0 <br />Density <br />Hand Placed/Shovel-Sliced and <br />rr <br />Tamped in <br />Compaccally t <br />Layers, o95% <br />Standard Proctor Density <br />Unsuitable Material: <br />Remove Unsuitable Material as <br />Required and Place Class I or <br />II Material per ASTM D2321 <br />Single Outlet Use <br />or Tee Double 0t <br />may be Wye or <br />Flowable Fill <br />(Removable) <br />Encasement Min. <br />6" Around Stack <br />Pipe <br />30' Curve Along - <br />Radius <br />L <br />Sewer Main Flow <br />Vitrified Plug <br />Tee Shown 90' <br />out of Position <br />L <br />6 <br />OA <br />PLAN <br />7. Slope <br />r.r ft. <br />Compacted <br />Tren ch Wall <br />Flowable Fill <br />r. (Removable) at <br />Main Branch <br />Flowable Fill <br />(Removable) at Wye Branch <br />Branch <br />VERTICAL STACK <br />NOTES: SLANT STACK <br />1. Refer to INDOT Standard Specification Section 213 for removable flowable fill requirements. <br />2. Wye replacement: Remove old wye, trim existing as pipe required, install new wye and pipe and <br />connect to existing pipes with Fernco couplings. <br />VERTICAL AND SLANT STACKS <br />(NOT TO SCALE) <br />Apply a Non -Petroleum <br />Based Releasing Agent <br />ent <br />to Casting when Paving <br />Heavy Duty Casting <br />(See Notes Below) <br />12" Max. Adjustment <br />24" Clear <br />Pre -Cast Opening <br />Manhole Riser <br />Section <br />Finished <br />Flexible Butyl Joint Sealant and Grout <br />Between Joints / Rings (Typ.) <br />Pre -Cost Concrete Adjusting Rings <br />to Bring Frame to Grade. Adjust <br />w/ 2" Rings to Bring Frame to <br />Grade. Bottom Ring Shall be 4" <br />Height. All Casting Grade <br />Adjustments Shall Follow INDOT <br />Pevoiling Specifications Section <br />720.04 <br />SECTION VIEW <br />NOTES: <br />1. Manhole castings shall be Heavy Duty (H-20 rated). Castings shall be East Jordan Iron Works 1040A <br />or Neenah R-1642. <br />2. Casting lid shall be solid with two (2) concealed pickholes for sanitary or combined sewer manholes <br />and two (2) open pickholes for storm sewer manholes. The text SANITARY shall be cast into the <br />lid for the sanitary or combined sewer manholes. The text STORM shall be cast into the lid for <br />storm sewer manholes. <br />3. Where directed by the City, casting lids shall bolt down. Bolts shall be provided with an <br />anti -seizing agent. <br />4. For manholes 72-inch diameter and larger, the clear opening shall be 36-inch diameter. The <br />casting shall be Heavy Duty (H-20 Rated). Casting shall be East Jordan Iron Works V-1600-5 or <br />Neenah R-1741-D. <br />5. For casting adjustments of existing brick manholes, remove old bricks down to a solid base. Then <br />level with mortar and build up with pre -cast adjusting rings. <br />6. When manholes are located in gravel or treelown areas, provide a 5 foot diameter concrete collar, <br />centered on the casting. Concrete shall be Class A. <br />TYPICAL MANHOLE CASTING & ADJUSTING RINGS <br />(NOT TO SCALE) <br />Tapping Area 120' <br />?ntal Axis <br />7A <br />Core Drill and <br />Seal Water Tight <br />Maximum 1" Protrusion df <br />R Into Exist. Pipe <br />Sewer Main Flow <br />NOTES.- <br />1. When "dr ) "D" use wye. <br />2. When "df" < "D" use manufactured saddle or if not available cut tap pipe per sketch. <br />SEWER TAPPING STANDARD <br />(NOT TO SCALE) <br />Specifications: <br />Sanitary Sewer: <br />1. Sanitary sewer construction, including appurtenances, shall meet the City of South <br />Bend standard specifications and drawings, not otherwise in conflict with, <br />specifications and drawings shown on these plans. <br />2. Sanitary sewer shall be installed in a dry trench. <br />3. Pre -cast concrete pipe manhole rings shall conform to the requirements of ASTM <br />C-478. <br />4. Sanitary sewer pipe shall be polyvinyl chloride pipe (P.V.C.) conforming to ASTM <br />D-3034, type PSM SDR-35, with elastomeric gasket joints conforming to ASTM <br />D-3212. Sanitary sewer pipe in excess of 12 ft. deep shall be P.V.C. SDR-26 or SDR <br />21. <br />5. Standard manholes shall be 48 inches pre -cast concrete conforming to ASTM C-478 <br />with pre -cast base or base to be constructed of class A concrete with a <br />semi -circular shaped bottom having a radius equal to the sewer section. All joints <br />to be made with bitumastic material and rubber gaskets conforming to ASTM C-443. <br />Castings to be NEENAH R-1642 or equivalent, conforming to ASTM A-48. Rubber <br />gasket to be used where P.V.C. pipe enters manholes. All pipe connections to <br />manholes shall be made with integral resilient fittings complying with ASTM C-923. <br />6. 6 inch diameter sanitary sewer service laterals shall be made with wyes and <br />according to the City of South Bend standards. At the end of all 6 inch sanitary <br />services, the contractor shall plug and place a 4" x 4" stake and a #4 rebar from 1 <br />foot below the invert to approximately 1 foot above the ground surface. <br />7. Low pressure air leakage testing shall be performed by the contractor in accordance <br />with the City of South Bend standards and ASTM F1417, standard test method for <br />installation acceptance of plastic gravity sewer lines using low-pressure air. The <br />contractor shall notify (3 working days in advance) the City of South Bend and <br />Abonmarche Consultants so that both may be present. Copies of the test results, <br />certified by a professional engineer, shall be submitted to the City of South Bend <br />Engineering Department, and Abonmarche Consultants L.L.C. Contractor shall provide <br />sewer test schedule to the Cityof South Bend Engineering Department and the <br />9 9 P <br />engineer so that both may be present. <br />8. Tests for deflection of sanitary sewer pipes shall be performed by the contractor not <br />prior to 30 days after installation b the contractor with an approved mandrel. The <br />P Y Y PP <br />contractor shall notify (3 working days in advance) the City of South Bend and <br />Abonmarche Consultants so that both may be present. No pipe shall exceed a <br />deflection of five (5%) percent. In the event the sanitary sewer pipe fails the <br />deflection test, the section of pipe which failed shall be completely removed, replaced <br />and re -tested starting with infiltration through deflection testing. Copies of the test <br />results, certified by a professional engineer, shall be submitted to the City of South <br />Bend Engineering Department and Abonmarche Consultants, L.L.C. The contractor <br />shall provide sewer test schedule to the City of South Bend Engineering Department <br />and the engineer so that both may be present. <br />9. All sewer fittings shall conform to the requirements of ASTM D-3 034 specifications <br />with minimum wall thickness of SDR 35 (as defined in 7.4.1) and shall be molded in <br />one piece with elastomeric joints and minimum socket depths as specified in <br />sections 6.2 and 7.3.2. P.V.C. material shall have a cell classification of 12454-B <br />and C as defined in ASTM D-1784. <br />10. The contractor shall verify the water table and include in the bid the cost to <br />de -water. The contractor shall lower the water table to 12 inches below the pipe <br />invert prior to installation. <br />11. Unsuitable materials that could affect the integrity of the lines should be properly <br />treated. <br />12. Sanitary sewer manholes shall be tested by negative air pressure in accordance with <br />ASTM C 1244 93. The contractor shall provide sewer test schedule to the City of <br />South Bend Engineering Department and the engineer so that both may be present. <br />13. A minimum of one compaction test will be required on the backfill for each sewer <br />pipe under the pavement. See Section 4-4 of COSB Standards. <br />14. Sewer televising will be required prior to acceptance (COSB Standards 4-4.2(h)). <br />MH <br />�O <br />1. Location of tap from downstream manhole. <br />2. Downstream manhole number. <br />3. Length of lateral from main to stub. <br />4. Depth of lateral at end. <br />As -Built Detail <br />-Not to Scale - <br />Note: <br />Sanitary laterals shall be installed below water main or at least 8 feet deep at the curb when <br />main depth allows. When the main depth is less then 8 feet, the laterals shall be installed <br />as deep as possible. <br />o o <br />>>D- <br />i <br />U o 0 0> o <br />U <br />U <br />Q <br />-0 a 0 <br />_>C= <br />o °�= a <br />0�000 <br />w <br />ZZ <br />O <br />Z <br />Z <br />m <br />0 <br />w <br />�� <br />E <br />0 <br />0Z Q <br />Q <br />oZCD o <br />�00"t�� <br />i <br />' <br />C <br />3��-i <br />Lo <br />11. <br />, 0 Lo <br />co v, H LL O U <br />U <br />M <br />Z <br />O <br />Q <br />VCL <br />>. <br />H <br />Z <br />W <br />H <br />Z <br />Q <br />_ <br />H <br />Z <br />�3:OZ <br />QOV <br />0 <br />Z <br />W <br />ll <br />t- <br />v <br />QUO0 <br />Ix <br />�C�y0 <br />W <br />� <br />0 <br />H <br />J <br />U <br />LU <br />O <br />N>f <br />J <br />Q <br />H <br />W <br />W <br />300 <br />H <br />H <br />Z <br />UJ <br />UJ <br />H <br />w <br />UJ <br />DRAWN BY: <br />DEF <br />DESIGNED BY: <br />RAD <br />PM REVIEW: <br />SDR <br />QA/QC REVIEW: <br />DATE: <br />2-21-2024 <br />SEAL: <br />�.......... <br />\STE,.�F-�'o <br />o• <br />:No. PE19900163's = <br />STATE OF t <br />SIGNATURE: <br />DATE: <br />3-4-2024 <br />SCALE: <br />HORZ: AS SHOWN <br />VERT: <br />ACI JOB # <br />23-1875 <br />SHEET NO. <br />16 of 22 <br />