Laserfiche WebLink
NOTES: <br />1. All curb to be constructed of class "A" concrete. <br />2. Control joints to be placed every 10'. <br />3. Expansion joints to be placed every 80' or as specified on construction drawings.14"8"7" <br />1"6"1" <br /> <br />R <br />2 <br />" <br /> <br />R <br />2.0% <br />1'-5" <br />2'-0" <br />2.0% <br />6" <br />HMA Base Course <br />HMA Base Course (As Req'd) <br />Subgrade Treatment <br />2'-0" <br />6/26/18 <br />CITY OF SOUTH BENDItemRevision <br />STANDARD <br />EFFECTIVE DATE: <br />REF STD SPEC SEC <br />APPROVED/REVISED BY THE BOARD OF PUBLIC WORKS <br />STANDARDS FOR DESIGN <br />AND CONSTRUCTION <br />Kara M. Boyles, Ph.D., P.E. Date <br />DETAILS - COMBINATION CURB AND GUTTER, TYPE B 2-33 <br />2-2 <br />June 26, 2018 <br />SECTION 2 - STREETS AND PATHS