Laserfiche WebLink
2'-0"12"8"1'-0" <br />4 <br />" <br /> <br />R <br />1' <br />-2" <br /> R <br />1 4" R24" - #4 Rebar @ 36" C.C. <br />NOTES: <br />1. All curb to be constructed of class "A" concrete. <br />2. Control joints to be placed every 10'. <br />3. Expansion joints to be placed every 80' or as specified on construction drawings. <br />4. Eliminate longitudinal bars if roadway is asphalt pavement. <br />5. Curb depth at pavement edge shall match pavement depth where concrete is used.6/26/18 <br />CITY OF SOUTH BENDItemRevision <br />STANDARD <br />EFFECTIVE DATE: <br />REF STD SPEC SEC <br />APPROVED/REVISED BY THE BOARD OF PUBLIC WORKS <br />STANDARDS FOR DESIGN <br />AND CONSTRUCTION <br />Kara M. Boyles, Ph.D., P.E. Date <br />DETAILS - COMBINATION CURB AND GUTTER, TYPE A 2-32 <br />2-2 <br />June 26, 2018 <br />SECTION 2 - STREETS AND PATHS