My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PSA - Demolition of SB Med. Foundation Project No. 123-076 – American Structurepoint, Inc.
sbend
>
Public
>
Public Works
>
Board of Works Documents
>
2024
>
Agreements/Contracts/Proposals/Addenda
>
PSA - Demolition of SB Med. Foundation Project No. 123-076 – American Structurepoint, Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2024 3:39:19 PM
Creation date
2/13/2024 3:39:00 PM
Metadata
Fields
Template:
Board of Public Works
Document Type
Contracts
Document Date
2/13/2024
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2 <br /> <br /> <br /> <br />Mr. Robert S. Bray Sr. January 30, 2024 <br /> <br />items suspected as ACMs and the inspector’s experience. As part of the survey, August <br />Mack will identify the number and locations of bulk material samples necessary to <br />sufficiently characterize areas that contain potential ACMs. The survey will be conducted <br />following the inspection and sampling methodologies specified in the U.S. EPA Asbestos <br />Hazardous Emergency Response Act (AHERA) Guidelines. In addition, the asbestos <br />inspection will be performed for demolition and, therefore, be compliant with the <br />National Emission Standard for Hazardous Air Pollutants (NESHAP) regulations. As <br />such, August Mack will sample or assume, photo document, and quantify all regulated <br />ACMs and Category I and II non-friable ACMs identified. <br /> <br />August Mack personnel will transport the bulk material samples collected during the <br />inspection using strict chain-of-custody documentation. The samples will be submitted to <br />EMSL Analytical Laboratories, Inc. (EMSL), a National Voluntary Laboratory <br />Accreditation Program (NVLAP) accredited laboratory. The samples will be analyzed by <br />polarized light microscopy (PLM) augmented with dispersion staining as specified in U.S. <br />EPA Method 600/M4-82-020 on a 1 week turn-around time. <br /> <br />It should be noted that this survey is for pre-demolition requirements, and all targeted <br />spaces will be visually inspected for potential ACMs, including the attic, interior wall <br />cavities, and mechanical chases. Therefore, damage will be incurred to building materials <br />as part of the investigation and sampling process in an attempt to uncover all potential <br />ACMs. If there are areas that are not reasonably accessible due to safety hazards or <br />construction of the space, the client will be notified immediately, and these areas will be <br />noted in the report. It should also be noted that all non-friable materials, except for floor <br />tiles and mastics on concrete, will be documented, quantified, and assumed as asbestos- <br />containing materials. During demolition activities, these materials can remain in place <br />and be disposed of as general construction waste at a construction and demolition <br />(C&D) landfill. <br /> <br />Reporting <br />Upon completion of the asbestos inspection and receipt of all sampling results, one (1) <br />pre-demolition asbestos survey report will be prepared. The report will include a <br />summary of the survey and sampling methodologies, asbestos bulk sampling results with <br />interpretation, and findings and conclusions for the project. Any areas that were not <br />accessible or any unforeseen obstacles encountered during the inspection will be noted. <br /> <br />COST INFORMATION <br /> <br />The Estimated Lump Sum Cost to perform the work described above is $47,800. This cost <br />includes project preparation, mobilization and inspection activities, laboratory analysis, <br />and preparation of the final report documenting the survey results. The cost presented <br />above is based on the following assumptions: <br /> <br />DocuSign Envelope ID: 8E7BADB5-C527-4326-B36C-C459763FF219
The URL can be used to link to this page
Your browser does not support the video tag.